Expanded operating temperature
Specifications
For temperatures between 35°C and 40°C, de-rate
maximum allowable temperature by 1°C per 175 m above
950 m (1°F per 319 ft).
≤ 1% of annual operating hours
–5°C to 45°C at 5% to 90% RH with 29°C dew point.
NOTE: Outside the standard operating temperature
(10°C to 35°C), the system can operate down to –5°C
or up to 45°C for a maximum of 1% of its annual
operating hours.
For temperatures between 40°C and 45°C,de-rate
maximum allowable temperature by 1°C per 125 m above
950 m (1°F per 228 ft).
NOTE: When operating in the expanded temperature range, system performance may be impacted.
NOTE: When operating in the expanded temperature range, ambient temperature warnings maybe
reported on the LCD panel and in the System Event Log.
Expanded operating temperature restrictions
• Do not perform a cold startup below 5°C.
• You must have six fans configured on your system.
• The operating temperature specified is for a maximum altitude of 3048 m (10,000 ft)
• Express Flash is not supported.
• GPU is not supported.
• 160 W workstation CPU is not supported.
• Internal TBU (Tape Backup Unit) is not supported.
• Two power supplies in redundant mode are required, but do not support PSU failure function.
• Non Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported.
• PCIe SSD is not supported
• Eighteen 3.5 inch hard-drive configuration is not supported
• Fusion IO is not supported.
43