Error Code
Message Information
PSU1201
Message
Power supply redundancy is lost.
Details
The power supply tries to operate in a degraded state. System
Performance and power redundancy may be degraded or lost.
Action
Check input power. Reinstall the power supply. If the issue persists,
see
Getting Help
.
PSU1204
Message
The power supplies are not redundant. Insufficient resources to
maintain normal operations.
LCD Message
PSU redundancy degraded. Check PSU cables.
Details
The current power operational mode is non-redundant because of a
power supply exception, a power supply inventory change, or a
system power inventory change.
Action
Check the event log for power supply failures. Review system
configuration and power consumption.
PWR1004
Message
The system performance degraded because power capacity has
changed.
Details
The system may power down or operate in a performance degraded
state.
Action
Check the event log for power supply failures. Review system
configuration and power consumption and upgrade or install power
supplies accordingly.
PWR1005
Message
The system performance degraded because the user-defined power
capacity has changed.
Details
The user-defined power settings have affected system operation.
Action
If unintended, review system configuration changes and power
policy.
PWR1006
Message
The system halted because system power exceeds capacity.
LCD Message
System power demand exceeds capacity. System halted.
Details
The system halted because system power exceeds capacity.
Action
Review system configuration, upgrade power supplies or reduce
system power consumption.
RFM1008
Message
Failure detected on Removable Flash Media <
name
>.
LCD Message
Removable Flash Media <
name
> failed. Check SD Card.
161
Summary of Contents for PowerEdge T420
Page 8: ...Diagnostic Messages 165 Alert Messages 165 10 Getting Help 167 Contacting Dell 167 ...
Page 40: ...40 ...
Page 126: ...126 ...
Page 136: ...136 ...
Page 148: ...148 ...
Page 166: ...166 ...