Error Code
Message Information
AMP0302
Message
The system board <
name
> current is greater than the upper warning
threshold.
Details
System board <
name
> current is outside of the optimum range.
Action
1.
Review system power policy.
2.
Check system logs for power related failures.
3.
Review system configuration changes.
4.
If the issue persists, see
Getting Help
.
AMP0303
Message
The system board <
name
> current is greater than the upper critical
threshold.
LCD Message
System board <
name
> current is outside of range.
Details
System board <
name
> current is outside of the optimum range.
Action
1.
Review system power policy.
2.
Check system logs for power related failures.
3.
Review system configuration changes.
4.
If the issue persists, see
Getting Help
.
ASR0000
Message
The watchdog timer expired.
Details
The operating system or an application failed to communicate within
the time-out period.
Action
Check the operating system, application, hardware, and system event
log for exception events.
ASR0001
Message
The watchdog timer reset the system.
Details
The operating system or an application failed to communicate within
the time-out period. The system was reset.
Action
Check the operating system, application, hardware, and system event
log for exception events.
ASR0002
Message
The watchdog timer powered off the system.
Details
The operating system or an application failed to communicate within
the time-out period. The system was shut down.
Action
Check the operating system, application, hardware, and system event
log for exception events.
150
Summary of Contents for PowerEdge T420
Page 8: ...Diagnostic Messages 165 Alert Messages 165 10 Getting Help 167 Contacting Dell 167 ...
Page 40: ...40 ...
Page 126: ...126 ...
Page 136: ...136 ...
Page 148: ...148 ...
Page 166: ...166 ...