About Your System
23
POST Error Codes
Collecting System Event Log for Investigation
Error Messages are logged in the System Event Log (SEL). The SEL can be
accessed through system BIOS and the BMC setup for investigation. You can
also access SEL by browsing to the IP address of the BMC.
Code
Log in BMC Cause
Corrective Actions
0000h
Yes
Timer Count Read/Write Error
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists, see
"Getting Help" on page 143.
0003h
Yes
CMOS Battery Error
See "Troubleshooting the
System Battery" on
page 118.
0004h Yes
CMOS Diagnostic Status Error
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists, see
"Getting Help" on page 143.
0005h
Yes
CMOS Checksum Error
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists, see
"Getting Help" on page 143.
000Bh
Yes
CMOS Memory Size Error
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists, see
"Getting Help" on page 143.