Running the Dell Diagnostics
5-9
because they require user interaction. Use
Pause for User Response
in situations
where you may want to prevent subtests that require user interaction from running—
such as when you run the diagnostics overnight.
2XWSXW'HYLFHIRU6WDWXV0HVVDJHV
Ordinarily, all status messages appear only on the screen.
Output Device for Status
Messages
allows you to direct status messages to either a printer or a file, in addition
to the screen. If you choose the
File
option, status messages are written to a file
named
result
. This file is automatically created on a diskette in drive A when you run
the diagnostics. If the
result
file already exists on the diskette, then new status mes-
sages are added to it.
The
result
file is an ordinary American Standard Code for Information Interchange
(ASCII) text file. You can access the
result
file with the MS-DOS
®
type
command as
follows:
1.
Select
Quit
to exit the diagnostics and return to the operating system prompt.
2.
At the operating system prompt, type the following command and press
<Enter>:
W\SHUHVXOW
The contents of the file appear on the screen.
After running particular diagnostic tests and viewing the status messages generated
by the tests in the
result
file, you can erase the contents of the file so that it is clear
for the next set of messages generated. Otherwise, the next messages are added at
the end of the previous ones in the file.
2XWSXW'HYLFHIRU(UURU0HVVDJHV
Ordinarily, all error messages appear only on the screen.
Output Device for Error
Messages
allows you to direct error messages to either a printer or a file, in addition
to the screen. If you choose the File option, error messages are written to the
result
file used for status messages. This file is automatically created on a diskette in drive A
when you run the diagnostics. If the
result
file already exists on the diskette, then
new error messages are added to it.
The
result
file is an ordinary ASCII text file. You can access and review the
result
file
with the MS-DOS
type
command as described in the previous subsection, “Output
Device for Status Messages.”
After running particular diagnostic tests and viewing the error messages generated by
the tests in the
result
file, you can erase the contents of the file so that it is clear for
the next set of messages generated. Otherwise, the next messages are added at the
end of the previous ones in the file.
Summary of Contents for POWEREDGE 4300
Page 1: ... ZZZ GHOO FRP HOO 3RZHU GJH 6 VWHPV 167 7 21 1 7528 6 227 1 8 ...
Page 8: ...x ...
Page 22: ...1 2 Dell PowerEdge 4300 Systems Installation and Troubleshooting Guide ...
Page 30: ...2 8 Dell PowerEdge 4300 Systems Installation and Troubleshooting Guide ...
Page 50: ...3 20 Dell PowerEdge 4300 Systems Installation and Troubleshooting Guide ...
Page 54: ...4 4 Dell PowerEdge 4300 Systems Installation and Troubleshooting Guide ...
Page 80: ...5 26 Dell PowerEdge 4300 Systems Installation and Troubleshooting Guide ...
Page 88: ...6 8 Dell PowerEdge 4300 Systems Installation and Troubleshooting Guide ...
Page 166: ...10 10 Dell PowerEdge 4300 Systems Installation and Trubleshooting Guide ...
Page 190: ...A 8 Dell PowerEdge 4300 Systems Installation and Troubleshooting Guide ...
Page 193: ...Jumpers Switches and Connectors B 3 LJXUH 6 VWHP RDUG XPSHUV jumpered unjumpered ...
Page 198: ...B 8 Dell PowerEdge 4300 Systems Installation and Troubleshooting Guide ...
Page 204: ...C 6 Dell PowerEdge 4300 Systems Installation and Troubleshooting Guide ...
Page 210: ...6 Dell PowerEdge 4300 Systems Installation and Troubleshooting Guide ...