10
General System Configuration
www
.dell.com | support.dell.com
8
Ensure that the
Mirror Pair
field for the remaining drive is set to
Secondary
.
The drive that is set to secondary will mirror the primary drive. All other data on the
secondary drive will be lost.
9
Press <Esc> to exit the
Adapter Properties Menu.
10
Select
Save changes and exit this menu
and press <Enter>.
After pressing <Enter>, you are prompted to confirm the change by pressing <Enter> again
and then by pressing <F3>.
11
Press <Esc> to exit the
Main Menu
.
12
Select
Exit the Configuration Utility
and press <Enter>.
The server module reboots and shows mirrored status after POST.
Additional Integrated Mirroring Guidelines
•
The hard-drive status indicator does not display any status information until after the
operating system driver initialization has occurred. To check for status information of a hard
drive prior to operating system load, use <Ctrl><M> during POST. See the
Dell PowerEdge
Expandable RAID Controller 4/IM User’s Guide
for more information. During normal
operation, the status indicator is off.
NOTE:
The hard-drive activity indicator functions normally before and after the operating system
driver initialization.
NOTICE:
If you use a drive with existing data, the data will be cleared before the hard drive is added to
a mirror.
•
It is recommended that any replacement drives should be blank and not previously
configured.
•
It is recommended that you replace hard drives in an integrated-mirror configuration with
drives of the same capacity.
•
After removing a hard drive in a hot-pluggable environment, wait at least 30 seconds prior
to installing the new hard drive.
Summary of Contents for PowerEdge 1855
Page 2: ......
Page 43: ...w w w d e l l c o m s u p p o r t d e l l c o m Dell PowerEdge 1855 系统 配置指南 ...
Page 106: ...104 Configuration générale du système w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 124: ...122 Configuration du commutateur KVM w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 150: ...148 Allgemeine Systemkonfiguration w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 168: ...166 Konfiguration des KVM Switchmoduls w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 169: ...w w w d e l l c o m s u p p o r t d e l l c o m Dell PowerEdge 1855 システム 設定ガイド ...
Page 213: ...w w w d e l l c o m s u p p o r t d e l l c o m Dell PowerEdge 1855 시스템 구성 설명서 ...
Page 236: ...234 일반 시스템 구성 w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 278: ...276 Configuración general del sistema w w w d e l l c o m s u p p o r t d e l l c o m ...