2-806
Cisco Catalyst Blade Switch 3120 for HP Command Reference
OL-12248-03
Chapter 2 Cisco Catalyst Blade Switch 3120 for HP Cisco IOS Commands
system env temperature threshold yellow
system env temperature threshold yellow
Use the
system env temperature threshold yellow
global configuration command on the switch stack
or on a standalone switch to configure the difference between the yellow and red temperature thresholds
that determines the value of yellow threshold. Use the
no
form of this command to return to the default
value.
system env temperature threshold yellow
value
no system env temperature threshold yellow
value
Syntax Description
Defaults
These are the default values:
•
Yellow—80°C
•
Red—85°C
Command Modes
Global configuration
Command History
Usage Guidelines
You cannot configure the green and red thresholds but can configure the yellow threshold. Use the
system env temperature threshold yellow
value
global configuration command to specify the
difference between the yellow and red thresholds and to configure the yellow threshold. For example, if
the red threshold is 66 degrees C and you want to configure the yellow threshold as 51 degrees C, set
the difference between the thresholds as 15 by using the
system env temperature threshold yellow 15
command.
Note
The internal temperature sensor in the switch measures the internal system temperature and might vary
±
5 degrees C.
value
Specify the difference between the yellow and red threshold values (in Celsius). The
range is 10 to 25. The default value is 10.
Release
Modification
12.2(40)EX1
This command was introduced.