Figure 64. Installing the LOM riser card
Next steps
1
If removed, install the risers. For more information, see
Installing the expansion card risers
2
Install the air shroud. For more information, see
.
3
Follow the procedure listed in
After working inside your system
.
Mini PERC card
Your system includes a dedicated expansion card slot on the system board for the primary storage controller card. The mini PERC card
provides the storage subsystem for internal drives of your system. The mini PERC card supports SAS and SATA drives and also enables you
to set up the drives in RAID configurations as supported by the version of the mini PERC card.
Removing the mini PERC card
Prerequisites
1
Follow the safety guidelines listed in
2
Follow the procedure listed in
Before working inside your system
.
3
Remove the air shroud. For more information, see
.
4
If installed, remove the right riser. For more information, see
Removing the expansion card risers
.
Steps
1
Using a Phillips #2 screwdriver, loosen the captive screws that secure the cable to the mini PERC card.
2
Holding the tab, lift the cable to disconnect it from the mini PERC card.
3
Slide out the mini PERC card to disengage from the card holder on the system board.
4
Lift the mini PERC card out of the system.
102
Installing and removing system components