![Dell EMC PowerEdge 14G Series Manual Download Page 34](http://html1.mh-extra.com/html/dell-emc/poweredge-14g-series/poweredge-14g-series_manual_2468280034.webp)
Chapter 5: Deploying SAN Storage
34
Dell EMC Ready Stack: Microsoft Hyper-V on PowerEdge 14G Servers and Unity Storage
Deployment Guide
The following table provides sample sizing information that is based on the function of the
management VM.
Table 8.
Management VM size example
Component
VMs
RAM (GB)
Operating
system (GB)
SCVMM server
1
16
240
SCVMM database
1
8
240
SCVMM library
1
4
240
SCVMM console
1
4
240
SQL Server
Note:
Additional SQL Server VMs and
database instances might be required. For
more information, see the Microsoft SCVMM
and SCOM documentation.
1
8
240
SCOM
If additional roles are required, see
requirements for System Center Operations
Manager
1
8
240
OMIMSSC
Integration Version 7.0 for Microsoft System
Center Installation Guide
1
8
See the
installation
wizard for
details.
Storage deployment and configuration checklist
Ensure that the following storage deployment and configuration tasks are complete:
Unity storage is deployed.
Connectrix DS6500 switches are deployed.
Storage and server zoning is configured.
Servers have FC access to Unity storage.
The management LUN has been presented to the management servers.
Management VM
sizing example