Dell EMC Ready Stack: Microsoft Hyper-V on PowerEdge 14G Servers and Unity Storage
Deployment Guide
Introduction
This chapter describes how to configure this Ready Stack for Networking S3048-ON OOB
management and S5248F-ON ToR switches. These steps are provided as an example of a
working configuration. Ensure that you review the steps with your site networking team
before performing them.
Note:
This Ready Stack solution supports other switch models in the Dell EMC Networking
portfolio, such as the S4148T-ON and the S5232-ON switches. However, the S5232F-ON and
S3048-ON switches that this sample configuration uses do not require additional breakout cabling
for lower-link speed devices and may help reduce cost and cabling complexity.
This networking site survey topology is intended as an example. Before starting
deployment, complete the full survey, which is available in
Confirm all the information in the following tables, especially Spanning Tree Protocol
(STP) information, with the personnel who are responsible for the network configuration in
your environment.
Table 2.
Switch hostnames example
Switch
Hostname
VLT backup address
VLT ports
S3048-ON
SWOOB
S5248F-Top
SW1
192.168.1.253/24
Ethernet 1/1/53-1/1/54
S5248F-Bottom
SW2
192.168.1.252/24
Ethernet 1/1/53-1/1/54
Table 3.
VLAN information example
Network
type
VLAN
ID
S5248F-Top
IP CIDR
S5248F-Bottom
IP CIDR
VRRP IP
address
VRRP
group
S3048-ON IP
OOB
100
172.90.100.252/24
172.90.100.253/24
172.90.100.254
1
172.90.100.25
Management
110
172.90.110.252/24
172.90.110.253/24
172.90.110.254
2
Live
migration
120
172.90.120.252/24
172.90.120.253/24
172.90.120.254
3
Compute
210
172.90.210.252/24
172.90.210.253/24
172.90.210.254
4
Table 4.
Customer network services example
Service
IP address
Core network gateway
172.90.100.250
Networking site
survey
information