Deployment Guide
5.
To verify that all the settings have been properly recorded, review the configuration
from enable mode by running the following command:
SW1# show running-config
6.
Repeat the preceding steps to configure the bottom Dell EMC Networking
S5248F-ON switch in the configuration.
The Networking S3048-ON switch connects to the network through the Networking
S5248F-ON switches using a port channel that consists of one interface on each
Networking S5248F-ON switch. Follow these steps:
1.
Configure the port-channel that will be used by running these commands:
SW1(config)# interface port-channel 101
SW1(conf-if-po-101)# description “OOB uplink”
SW1(conf-if-po-101)# no shutdown
SW1(conf-if-po-101)# switchport mode trunk
SW1(conf-if-po-101)# switchport trunk allowed vlan
100,110,120,210
SW1(conf-if-po-101)# mtu 9216
SW1(conf-if-po-101)# vlt-port-channel 101
SW1(conf-if-po-101)# exit
2.
Configure the port that will be used for the port channel by running these
commands:
SW1(config)# port-group 1/1/12
SW1(conf-pg-1/1/12)# mode Eth 10g-4x
SW1(conf-pg-1/1/12)# exit
SW1(config)# interface ethernet 1/1/48:1
SW1(conf-if-eth1/1/48:1)# no shutdown
SW1(conf-if-eth1/1/48:1)# description “OOB uplink”
SW1(conf-if-eth1/1/48:1)# channel-group 101 mode active
SW1(conf-if-eth1/1/48:1)# mtu 9216
SW1(conf-if-eth1/1/48:1)# exit
3.
Repeat the preceding steps to configure the bottom Dell EMC Networking S5248F-
ON switch.
Configure the