Dell EMC Ready Stack: Microsoft Hyper-V on PowerEdge 14G Servers and Unity Storage
Deployment Guide
Table 5.
Switch port mappings example
Component
S5248F-Top
S5248F-Bottom
S3048-ON
Server
NIC Port 1
NIC Port 2
iDRAC
Mgmt1
Ethernet 1/1/1
Ethernet 1/1/1
Ethernet 1/1/1
Mgmt2
Ethernet 1/2/1
Ethernet 1/2/1
Ethernet 1/2/1
Comp1
Ethernet 1/3/1
Ethernet 1/3/1
Ethernet 1/3/1
Comp2
Ethernet 1/4/1
Ethernet 1/4/1
Ethernet 1/4/1
Comp3
Ethernet 1/5/1
Ethernet 1/5/1
Ethernet 1/5/1
You need a laptop with a serial connection and terminal emulation software such as
PuTTY.
This guide uses certain typographical conventions to mark commands and screen output.
Information that is specific to your environment or site survey is placed inside <> symbols
and presented in italics. For example:
Deployment guide command reference:
OS10(config)# hostname
<hostname>
On the top S5248F-ON switch, enter:
OS10(config)# hostname SW1
On the bottom S5248F-ON switch, enter:
OS10(config)# hostname SW2
When an input command is different between the top and the bottom switch but the
information is not part of the site survey, an indentation identifies the different commands.
Use the command with the preceding hostname for the switch you are configuring. For
example:
SW1(config)# spanning-tree mode rstp
#Command entered on both
switches
SW1(config)# spanning-tree rstp priority 4096
#Command for
Top S5248F-ON
SW2(config)# spanning-tree rstp priority 8192
#Command for
Bottom S5248F-ON
Screen output is presented in
bold
. Optional commands are shown in
bold
italics
.
Prerequisites
Typographical