Foreign configuration found error message..................................................................................................................66
Foreign configuration not found in HII error message.................................................................................................66
Degraded state of virtual disks....................................................................................................................................... 67
Memory errors..................................................................................................................................................................67
Preserved Cache State................................................................................................................................................... 67
Security key errors........................................................................................................................................................... 67
Secured foreign import errors...................................................................................................................................67
Failure to select or configure non Self-Encrypting Disks non-SED..................................................................... 68
Failure to delete security key.................................................................................................................................... 68
Failure of Cryptographic Erase task on secured physical disks............................................................................68
Physical disk in failed state....................................................................................................................................... 69
Unable to rebuild a fault tolerant virtual disk.......................................................................................................... 69
Fatal error or data corruption reported................................................................................................................... 69
Physical disk displayed as blocked........................................................................................................................... 69
Multiple disks become inaccessible......................................................................................................................... 69
Rebuilding a failed physical disk................................................................................................................................70
Virtual disk fails during rebuild using a global hot spare.........................................................................................70
Virtual disk fails during rebuild using a dedicated hot spare..................................................................................70
Physical disk fails during reconstruction on redundant virtual disk......................................................................70
Virtual disk fails rebuild using a dedicated hot spare..............................................................................................70
Physical disk takes a long time to rebuild.................................................................................................................71
Virtual disk policy is assumed as write-through error message............................................................................72
Unable to register SCSI device error message.......................................................................................................73
Disk carrier LED indicators.............................................................................................................................................. 73
HII error messages........................................................................................................................................................... 74
Summary of RAID levels..................................................................................................................................................75
RAID terminology............................................................................................................................................................. 76
Disk striping.................................................................................................................................................................76
Disk mirroring..............................................................................................................................................................76
Spanned RAID levels.................................................................................................................................................. 77
Parity data................................................................................................................................................................... 77
6
Contents