NOTE:
Consistency check cannot be run on RAID 0 virtual disks.
4
From the
Operations
drop-down menu, select
Check Consistency
.
5
Click
Go
.
A screen is displayed asking if you are sure you want to perform the operation.
6
Select the
Confirm
option.
7
Click
Yes
.
The consistency check operation is completed successfully.
Physical disk management
Viewing physical disk properties
1
Enter the
Dell PERC 10 Configuration Utility
Navigating to Dell PERC 10 configuration utility
2
Click
Main Menu
>
Physical Disk Management
.
All the physical disks associated with the RAID controller are displayed.
3
To view the properties, click on the physical disk. The following properties can be viewed on the physical disk:
Table 11. Physical disk properties
Option
Description
Operation
List of operations you can perform on the selected physical disk. The
options are:
•
Blink
•
Unblink
•
Force Offline
•
Replace Member
•
Erase Options
•
Global and Dedicated hotspare
•
Convert to RAID Capable
•
Convert to Non-RAID Disk
Device ID
Unique identifier of the physical disk.
Connection
Number of paths and how wide the paths are to the physical disk.
Indicated if a physical disk is in a multipath configuration for H745P MX
and H840.
Backplane ID
Backplane ID in which the physical disk is located in for H740P, H740 mini,
and H745P MX.
Enclosure Position
The enclosure in which the physical disk is located for H840.
Chassis Slot Value
The chassis slot value of the chassis slot in which the physical disk is
located when the physical disk is in a MX 5016s storage sled for the
controller H745P MX.
Slot Number
The drive bay in which the physical disk is located for the corresponding
backplane or enclosure to which the controller is connected.
Status
Status of the physical disk.
Size
Size of the physical disk.
56