Step 6
- With the chlorinator cell now mechanically detached,
access the two small electrical connectors for the flow switch
and the temperature sensor and disconnect these connectors
from chlorinator cell. The connectors have a locking feature
that must be raised to separate the connector plug and socket.
Remove the chlorinator cell from the TrioPure
TM
enclosure.
5d-4 Air Filters
The TrioPure
TM
has screen filters located at both the cooling fan
air intake on the right side of the enclosure and the air exhaust
at the bottom of the enclosure (
Figure 26
). The screen filters are
intended to keep insects and debris out of the TrioPure
TM
unit.
Allowing these screen filters to become clogged could result in
the TrioPure
TM
shutting down to protect from overheating.
Annual inspection and
cleaning of the screen
filters is recommended
as follows:
TrioPure
TM
Sanitation System
DEL Ozone · San Luis Obispo, CA 93401 · USA · 800-676-1335 · Fax: 805-541-8459
Step 5
- With one hand supporting the chlorinator cell in the middle, unscrew the right hand side attachment knob. As this knob
is unscrewed, the chlorinator cell will lower. Use caution and do not allow the weight of the chlorinator cell to stress the wires on
the electrical connectors.
19
2) Disconnect quick
disconnect fitting
4) Remove attachment shaft
5) Remove chlorinator cell by turn-
ing knob counterclockwise
1) Turn power off
6) Disconnect the two small
electrical connectors
3) Remove the two electrical
connectors
Figure 25
Figure 26
Figure 27
Figure 28
Air In
take
Air Intake Screen
Filter:
Turn off power
to the TrioPure
TM
. Remove
the cover by sliding
the cover up (
Figure
27
). Once the cover is
removed, visually check
the filter for debris. If the
filter appears to require
cleaning, carefully remove plastic filter keeper (
Figure 28
) by lightly
prying it out. Remove the screen filter and clean it. Replace filter,
keeper and cover.
Air Exhaust
Air Exhaust Screen Filter:
The Air Exhaust filter should
typically not require servicing.
After removing the Chlorinator
Cell (See Section 5D-4), visu-
ally check the filter for debris.
If the filter appears to require
cleaning, then remove plastic
filter keeper by lightly prying it
out. Remove the screen filter,
clean and replace.
Lift (slide)
cover up for
filter access.
Lightly pry
here with
coin or
screwdriver
to remove
plastic filter
keeper.