18
TrioPure
TM
Sanitation System
5d-1 Injector
Visually check the injector (see Figure 19); if clogged,
there will be a noticeable reduction in ozone bubbles seen
through the Chlorinator Cell. If cleaning is required, turn off
power and water flow to the TrioPure
TM
. Remove the Chlo-
rinator Cell (See
Section 5D-3
). Remove the plug at the
injector and use the Injector Cleaning Tool (end of zip tie)
attached to the line going to the injector (or suitable small
plastic tool) to push material down through the injector
slot. Replace the Chlorinator Cell onto the TrioPure enclo-
sure.
Note:
Never use a metal tool to clean the injector slot.
5d-2 Chlorinator Cell Plate Cleaning
Option 1
- (Acid Solution Injection) Turn off power to the
TrioPure
TM
and main pool circuit breaker. Prepare a solution
of 4 parts water to 1 part Muriatic Acid. Always add acid to
water, never add water to acid. Disconnect the ozone line
going into the chlorinator cell. Connect the acid injection line
to the line going into the chlorinator cell. Turn on main circuit
breaker and power to the TrioPure and check the chlorinator
cell for bubbles at the injector. Place the other end of the Acid
Injection Line into the acid solution. Observe that the solu-
tion is being drawn up into the chlorinator cell. When the acid
solution has been used up, run clean water through the line to
clean acid from the line. Turn off power to the TrioPure
TM
and
re-connect the line onto the Chlorinator Cell to the line coming
from the enclosure. Turn on power to the TrioPure
TM
and check
the chlorinator cell for bubbles at the injector. Properly clean
and store the acid injection materials.
Option 2
- (acid soaking) Turn the power off to the TrioPure
TM
and main pool circuit breaker. Remove the chlorinator cell (See
Section 5D-3) and place on a level surface with the front of
the cell facing up. Install the elbow fitting to the union at the
Water Out location on the chlorinator cell. Prepare a solution
of 4 parts water to 1 part Muriatic Acid. Always add acid to
water, never add water to acid. Carefully pour acid solution
into the elbow fitting just until the Chlorinator Cell plates are
submerged. Allow the plates to soak for about 30 minutes, or
until effervescence stops and plates are clean. Take care not
to let the acid solution into the front chamber of the chlorinator
cell, as damage to the flow switch may result.
When the chlorinator cell plates appear to be clean (free of
calcium deposits), pour the acid solution from the chlorinator
cell into the swimming pool.
5d-3 Chlorinator Cell Removal
NOTE: CAREFULLY FOLLOW ACID MANUFACTURER’S SAFETY
PRECAUTIONS.
Step 1 -
Turn the power off to the TrioPure
TM
and main pool
circuit breaker. Close the two ball valves (if installed) to the
TrioPure
TM
and disconnect the union going to the chlorinator cell.
Step 2 -
Disconnect the fitting on the Lower Left Hand side of
the TrioPure
TM
by rotating the fittings halves in opposite direc
-
tions and separate the two halves.
Step 3 -
Remove the two electrical terminals by loosening the
small hand knobs on the right side of the chlorinator cell and
slipping the terminal lugs off the connector studs. If the termi-
nals are attached with ¼-20 nuts, remove the nuts to detach
the wires. Retain the stainless steel washers for reassembly.
Note the order of disassembly and reverse for reassembly.
Step 4 -
Remove the Left Hand Side Attachment shaft by
unscrewing the hand knob.
5-C WINTERIZATION (Continued)
Step 2
- Remove the drain plug from the bottom of chlorinator
cell and let all water drain from the TrioPure
TM
.
Step 3
- Replace drain plug back into the TrioPure
TM
.
Figure 22 - Chlorinator Cell Drain Plug
Figure 24 - Chlorinator Cell Plate Cleaning
DEL Ozone · San Luis Obispo, CA 93401 · USA · 800-676-1335 · Fax: 805-541-8459
Figure 23 - Acid Injection line
5-D TRIOPURE MAINTENANCE