2e-3 Plumbing Configurations (Continued)
Figure 3 -
(Existing Pool, Pool Only, ICS, Solar, No solar):
· Manifold to be plumbed between the filter and heater.
· TrioPure
TM
return port of the bypass manifold capped off.
· Return from TrioPure
TM
plumbed to the line of the ICS that goes to the lowest point of the pool.
- This is after the ICS diverter valve.
- A light duty check valve must be placed between the diverter valve and point where the TrioPure
TM
enters the ICS line.
· Del recommends installing 2 cm (¾”) ball valves on the inlet and outlet of the Triopure to facilitate Salt Cell removal for
cleaning and a ball valve after the Bypass Manifold to control water flow through the Salt Cell.
Figure 4 -
(New Pool, Pool Spa Combination, No ICS, No solar):
· Manifold to be plumbed in the pool return after the 3-way valve that diverts water between the pool and spa.
· TrioPure
TM
return port of the bypass manifold capped off.
· Return from TrioPure
TM
plumbed to a dedicated 2 cm (¾”) return to the lowest point of the pool.
· To minimize the size of ozone bubbles, use a dispersion cap or main drain cover. This may require a stub-up to the appro-
priate size for the fitting.
· Del recommends installing 2 cm (¾”) ball valves on the inlet and outlet of the Triopure to facilitate Salt Cell removal for
cleaning and a ball valve after the Bypass Manifold to control water flow through the Salt Cell.
TrioPure
TM
Sanitation System
5
DEL Ozone · San Luis Obispo, CA 93401 · USA · 800-676-1335 · Fax: 805-541-8459
A
ICS
POOL
SOLAR
HEATER
Optional
J
J
POOL
SPA
TrioPure
TM
TrioPure
TM