Rev 2022-03-08
Pharmafill Model TC4 User Manual
Deitz Company Inc.
TC4 User Manual
Page
25
9.
CLEANING – BREAKDOWN AND BUILDUP.
9.1.
BREAKDOWN OF REMOVE-TO-CLEAN CONTACT PARTS
1.
If equipped with the optional automatic feeder control, disconnect the electrical cable
connected to the AFC sensor by unscrewing it.
2.
Remove the clear rim cover – Loosen the front knob and rotate it up. Loosen the rear
knobs, lift and slide cover out.
3.
Remove the center hub – unscrew the knob and remove the hub.
4.
Remove the product guide assembly – unscrew the knob, slide the assembly to the right
and lift up.
5.
Rotate the air manifold assembly – pull the release pin and rotate the assembly up.
6.
Remove the rim band – starting at the front, lift the band out of its groove, working your
way around to the back.
7.
Remove the glass disc – unscrew the hold-down ring nut, remove the clear plastic washer
and lift off the glass.
8.
Remove the counting window and sensor – unlock the electrical cable by pulling the
black ring down, then disconnect it by pulling the connector down. Remove the counting
sensor by pulling down on the release clip at the bottom and rotating the sensor out.
Loosen the knob on the left side of the counting window and remove the window and
sensor as one piece. DO NOT let the window hang by the fiber optic cables. DO NOT
separate the fiber optic cables from the sensor.
9.
Remove the counting head clear front cover – unscrew the three knobs and remove the
cover.
10.
Remove the funnel holders and funnels – loosen the funnel knob and slide the funnel
holder and funnel out.
11.
Remove the left, right and center head blocks – slide the blocks off the mounting posts.
12.
Remove the funnel block – loosen the two knobs, letting the block drop until it is free.
13.
Remove the feeder pan sieve plate (if equipped with optional feeder) – loosen two knobs
and remove sieve plate.
14.
Remove the hopper door (if equipped with optional hopper) – remove two knobs and lift
door out of hopper.