Rev 2022-03-08
Pharmafill Model TC4 User Manual
Deitz Company Inc.
TC4 User Manual
Page
29
9.1.2.
STEP-BY-STEP BREAKDOWN – HEAD SECTION
Remove the counting window and
sensor – unlock the electrical cable by
pulling the black ring down, then
disconnect it by pulling the connector
down. Remove the counting sensor by
pulling down on the release clip at the
bottom and rotating the sensor out.
Loosen the knob on the left side of the
counting window and remove the
window and sensor as one piece. DO
NOT let the window hang by the fiber
optic cables. DO NOT separate the
fiber optic cables from the sensor.
Remove the clear front cover –
unscrew the three knobs and remove
the cover.