Rev 2022-03-08
Pharmafill Model TC4 User Manual
Deitz Company Inc.
TC4 User Manual
Page
19
7.4.3.2.
AIR GUIDES
The Air Guides work for all types of product (tabs, caps, etc.). They prevent jams
better than mechanical guides, are easy to adjust and are not prone to stoppages
that require an operator to clear.
To set the Air Guides, looses the knobs on the air guide blocks. Use the handle on
the air manifold to rotate the Air Jets so that the air flows just above the pills in the
channel. If set too low, the air will disturb the flow in the channel, impeding the
flow and possibly blowing pills right out of the channel. If set too high, faults
might not be rejected. Once set at the right height, tighten the knob.
FLOW DIVERTER
AIR MANIFOLD
HANDLE
FLOW GUIDE
(AIR TYPE)
AIR JETS