CYCLE OF OPERATION
When power is on, the counting function is active and anything that passes through the
counting window will be tallied.
Automatic Cycle
1. If RUN button is pressed (latch)
2.
Glass disc rotates at HIGH speed (set by potentiometer)
Feeder starts (if equipped)
If tally >= SLOWDOWN COUNT,
3.
Glass disc rotates at LOW speed (set by potentiometer)
If tally=TARGET COUNT
4.
Divider flag flips
Count tally reset to zero
Glass disc resumes HIGH speed
5. If RUN button is pressed again (unlatch)
Glass disc stops
Feeder stops (if equipped)
Manual Cycle
1. If MANUAL button is pressed (latch)
2.
Glass disc rotates at HIGH speed (set by potentiometer)
Feeder starts (if equipped)
If tally >= SLOWDOWN COUNT,
3.
Glass disc rotates at LOW speed (set by potentiometer)
If tally=TARGET COUNT
4.
Divider flag flips
Count tally reset to zero
Glass disc stops
Feeder stops
Excess pills are counted and tally is maintained
Check Count Cycle
1. If CHECK COUNT button is pressed (latch)
2.
Glass disc rotates at HIGH speed (set by potentiometer)
Feeder starts (if equipped)
5. If CHECK COUNT button is pressed again (unlatch)
Glass disc stops
Feeder stops (if equipped)
Count tally reset to zero