background image

 
 
COM 

The common terminal of negative polarity, in common with "-12V", is to be used for the interaction with 
the terminals ARM, FOG and FOG2. 

 

ARM 

(N.A. by default but modifiable N.C) 

Bringing to this input the continuous signal taken from the terminal 

COM or -12v

, it will emit a "beep" of 3 

seconds, followed by the "armament" of the device that will be ready to deliver at 100% after about 6-12 
min. (depending on the ambient temperature or how long it has been disarmed) when it is ready, it will 
emit a "beep" warning of a 1 second. 
 

If during the Armament the appliance emits an endless "beep", it means that there is also a signal on "FOG" 
or "FOG2" which must always be at rest during this phase, so keep them at rest and re-arm . 

 
If desired, it is possible to change the contact activation mode to "OPEN" (N.C.) turning ON the DipSwitch 
nr 3. In this case also "FOG" and "FOG2" will become N.C. 
 

 
FOG 

(N.A. by default but modifiable N.C.) 

When the device is "ARMED" and ready, carrying / removing a pulse lasting more than 0.5 "from 

the 

COM 

or -12V

 terminal to this input, the firing and forced pause cycle will start according to the times 

programmed through the DipSwitch as shown in the table on page 13. 
If desired, it is possible to change the contact activation mode to "OPEN" by turning ON the DipSwitch nr 3 
(Also ARM and FOG2 will be modified) 
 
At the end of the firing and forced pause cycle if the FOG input is still unbalanced, the cycle will start again. 
 

 

 

It is possible to set the FOG command in "Bistable" mode (checkout the “Special Functions” on page 13), 
i.e. the device will dispens until there is (or absent if N.C.) a signal on FOG. In any case, if the signal extends 
beyond the configured firing time, the dispens will stop as programmed, proceeding with the forced pause. 
 
When the signal is interrupted within the firing time, dispens is immediately stops and the forced pause 
time is also  skipped. 
 
The parameters set in the factory are: 
Shot time: 60 '' 
Forced pause: 10’ (used to prevent unnecessary shooting once the environment is saturated) 
Admission: N.O. (Normally Open) 
 

DIP-Switch configuration ON 1-2-6-9 

 

It is possible to 

INCREASE

 the duration of the shot up to 120 '' in 

pulsed mode

, turning ON the DipSwitch 

nr.8, the amount of fog will be the same but you will have the possibility to prolong the firing cycle. 

 
Note. This function doubles the firing time whatever the time that has been set (dip 1-2) 

 
 
 

Summary of Contents for DT-800Lan

Page 1: ...Manual of installation and maintenance Fog Generators DEFENDERTECHDT 800Lan...

Page 2: ......

Page 3: ...e power supply of the appliance must be supplied through a special switch or plug in order to allow it to be switched off Danger of burns the components of the appliance are subject to heating do not...

Page 4: ...ct then this will have to report their presence to the Producer on penalty of forfeiture within one week of discovery 4 The Customer provided that he has provided a timely description of the data cont...

Page 5: ...igation to display The legislation provides for the obligation to post in the access route of the premises a notice that signals the presence of a Fog Generator Use the adhesive label supplied with th...

Page 6: ...adjustable up to 200 mm Nozzles extension lengh adjustable up to 500 mm Fog jet diversion kit passes through the wall behind the equipment Fog jet split and diversion kit 50 passes through the wall be...

Page 7: ...THE APPLIANCE Use 4 10 mm dowels fisher of the type suitable for the wall on which the machine will be installed If necessary it is possible to drill the bracket at any point of it adjacent to the wa...

Page 8: ...2 Place the appliance on the front of the bracket and let the four fins of the bracket penetrate the side slits of the appliance operation 1 3 Slide the appliance down 2nd operation 4 Using a 4mm Alle...

Page 9: ...Description DT 800Lan Control Card...

Page 10: ...te This contact can be used to assign other functions see p 14 special features STATE system status failure signal When the appliance is disarmed or switched off the Clean NA contact normally open wil...

Page 11: ...ording to the times programmed through the DipSwitch as shown in the table on page 13 If desired it is possible to change the contact activation mode to OPEN by turning ON the DipSwitch nr 3 Also ARM...

Page 12: ...vating this function the Fog2 input takes on the task of preventing accidental firing If a negative signal is present on FOG2 the shot will not be allowed If the signal arrives while the shot is in pr...

Page 13: ...X X X PUMP MODE CONTINUE X X X X X X X OFF X X IMPULSIVE DOUBLE THE SHOT TIME X X X X X X X ON X X RESISTANCE NUMBER 1 X X X X X X X X OFF OFF 2 X X X X X X X X ON OFF X X X X X X X X X X X X X X X X...

Page 14: ...ORK SIGNALING OFF OFF X X X X X X X X LACK OF NETWORK SIGNALED ON STATE RELAY ON ON X X X X X X X X LACK OF NETWORK NON SIGNALED ON STATE RELAY LIQUID LEVEL CONTROL OFF X OFF X X X X X X X LIQUID LEVE...

Page 15: ...nctions of the Menus 1 and 2 you will have to program them simultaneously starting from those of the menu 1 activate the DIP10 and then the DIP corresponding to the desired functions of the Menu2 DIP...

Page 16: ...PAUSE STATE FIXED ON THE APPLIANCE IS IN THE FORCED PAUSE STATE it will ignore every firing commands untili its end ONE FLASH FOR EVERY RIARMAMENT OF THE MACHINE FAILURE LED6 RED TURNED OFF NO ALLARM...

Page 17: ...on peaks especially if there are more Fogs Generators or there is only one that is turned on 24H SHOT MANAGEMENT The shot is inhibited when the appliance is unarmed the burner temperature is lower tha...

Page 18: ...DT MultiFogControl is responsible for monitoring simultaneously the operating status of several Fogs Generators even in different geographical sites Both software can be requested free of charge by m...

Page 19: ...s incorrect reset the error by operating the DipSwitch no 5 if it persists the appliance will not work until it is replaced by the service DefenderTech LACK_NETWORK_ALARM self restoring lack of electr...

Page 20: ...re the liquid level to the 100 acting on DipSwitch nr 4 TECHNICAL INSTALLATION Once the machine is connected to the mains activate the buffer battery connecting the flying cable to the respective free...

Page 21: ...following is prescribed to Replace the buffer batteries 2x12V 1 3 are wired in series Arm the appliance by measuring voltage and absorption on the 230V mains Perform a full 60 second shot using water...

Page 22: ...1 DT 1600plus Lan 1601 DefenderTech Fog Generator Device Fog Genrator for safety applications They comply with the European Community Directives Low Voltage 2004 108 CE Electromagnetic Compatibily 200...

Page 23: ...ion directive C E E HAZARD IDENTIFICATIONS No specific danger can be found in the use of the effects PHYSICAL AND CHEMICAL PROPERTIES Physical state liquid Appearance and color liquid of transparent c...

Page 24: ...www defendertech eu info defendertech eu Tel 39 0721 1626113 Fax 39 0721 0731145...

Reviews: