MANAGEMENT OF MALFUNCTIONS: 

 
The "malfunction" (opening status contact and video-acoustic signals) is generated by the system if any of 
the following conditions should occur: 

 

LIQUIDI_LEVEL_ALARM

occurs when the liquid level is below 20% of the tank. 

When the estimated liquid in the tank end up, the system will allow a further 120 sec of firing (even if not 
consecutive) and after this it will not allow others. It will be necessary to intervene to restore correct 
operation, reloading the tank and setting the 100% level again using DipSwitch 4. 

 

CARD_OVERHEATING_ALARM

: (

self-resetting) occurs when the inside of the appliance has exceeded the 

maximum allowed temperature due to extreme weather conditions or bad installation (poor ventilation). 
 

ABSENT_BATERY_ALARM

: (self-resetting) the appliance will continue to operate until the 230Vac power 

supply will be present. 
 

FAULTY_SONDE_ALARM

: occurs when the thermocouple is disconnected or damaged or if the reading is 

incorrect, reset the error by operating the DipSwitch no. 5 if it persists, the appliance will not work until it 
is replaced by the service DefenderTech. 
 

LACK_NETWORK_ALARM

: (self-restoring) lack of electricity grid 

 
 

BURNER_OVERHEATING_ALARM

: reset the error by operating on Dip Switch no. 5 if it persists contact the 

DefenderTech service. 

 

PUMP_FAILURE_ALARM

it occurs when the pump does not work or does not suck up liquid from the tank. 

This signal does not affect the operation of the pumps, the machine will perform the firing procedure 
regardless. 
Reset the error by operating DipSwitch 5, if it persists contact the DefenderTech service. 
 

Check if there is liquid in the tank, otherwise the hose, the pump or the solenoid valve are faulty, contact 
the Service DefenderTech to be adviced on the action to be taken. 
 

 

RESITENCE_BROKEN_ALARM

: it 

occurs during the burner heating phase, if the temperature does not 

increase in the expected quantity when the resistance is activated. Reset the error by operating DipSwitch 
5, if it persists contact the DefenderTech service. 

 

 
 

All faults can be verified through the monitoring sw DT-FogControl and 

DT-MultiFogControl

 

 

 

Summary of Contents for DT-800Lan

Page 1: ...Manual of installation and maintenance Fog Generators DEFENDERTECHDT 800Lan...

Page 2: ......

Page 3: ...e power supply of the appliance must be supplied through a special switch or plug in order to allow it to be switched off Danger of burns the components of the appliance are subject to heating do not...

Page 4: ...ct then this will have to report their presence to the Producer on penalty of forfeiture within one week of discovery 4 The Customer provided that he has provided a timely description of the data cont...

Page 5: ...igation to display The legislation provides for the obligation to post in the access route of the premises a notice that signals the presence of a Fog Generator Use the adhesive label supplied with th...

Page 6: ...adjustable up to 200 mm Nozzles extension lengh adjustable up to 500 mm Fog jet diversion kit passes through the wall behind the equipment Fog jet split and diversion kit 50 passes through the wall be...

Page 7: ...THE APPLIANCE Use 4 10 mm dowels fisher of the type suitable for the wall on which the machine will be installed If necessary it is possible to drill the bracket at any point of it adjacent to the wa...

Page 8: ...2 Place the appliance on the front of the bracket and let the four fins of the bracket penetrate the side slits of the appliance operation 1 3 Slide the appliance down 2nd operation 4 Using a 4mm Alle...

Page 9: ...Description DT 800Lan Control Card...

Page 10: ...te This contact can be used to assign other functions see p 14 special features STATE system status failure signal When the appliance is disarmed or switched off the Clean NA contact normally open wil...

Page 11: ...ording to the times programmed through the DipSwitch as shown in the table on page 13 If desired it is possible to change the contact activation mode to OPEN by turning ON the DipSwitch nr 3 Also ARM...

Page 12: ...vating this function the Fog2 input takes on the task of preventing accidental firing If a negative signal is present on FOG2 the shot will not be allowed If the signal arrives while the shot is in pr...

Page 13: ...X X X PUMP MODE CONTINUE X X X X X X X OFF X X IMPULSIVE DOUBLE THE SHOT TIME X X X X X X X ON X X RESISTANCE NUMBER 1 X X X X X X X X OFF OFF 2 X X X X X X X X ON OFF X X X X X X X X X X X X X X X X...

Page 14: ...ORK SIGNALING OFF OFF X X X X X X X X LACK OF NETWORK SIGNALED ON STATE RELAY ON ON X X X X X X X X LACK OF NETWORK NON SIGNALED ON STATE RELAY LIQUID LEVEL CONTROL OFF X OFF X X X X X X X LIQUID LEVE...

Page 15: ...nctions of the Menus 1 and 2 you will have to program them simultaneously starting from those of the menu 1 activate the DIP10 and then the DIP corresponding to the desired functions of the Menu2 DIP...

Page 16: ...PAUSE STATE FIXED ON THE APPLIANCE IS IN THE FORCED PAUSE STATE it will ignore every firing commands untili its end ONE FLASH FOR EVERY RIARMAMENT OF THE MACHINE FAILURE LED6 RED TURNED OFF NO ALLARM...

Page 17: ...on peaks especially if there are more Fogs Generators or there is only one that is turned on 24H SHOT MANAGEMENT The shot is inhibited when the appliance is unarmed the burner temperature is lower tha...

Page 18: ...DT MultiFogControl is responsible for monitoring simultaneously the operating status of several Fogs Generators even in different geographical sites Both software can be requested free of charge by m...

Page 19: ...s incorrect reset the error by operating the DipSwitch no 5 if it persists the appliance will not work until it is replaced by the service DefenderTech LACK_NETWORK_ALARM self restoring lack of electr...

Page 20: ...re the liquid level to the 100 acting on DipSwitch nr 4 TECHNICAL INSTALLATION Once the machine is connected to the mains activate the buffer battery connecting the flying cable to the respective free...

Page 21: ...following is prescribed to Replace the buffer batteries 2x12V 1 3 are wired in series Arm the appliance by measuring voltage and absorption on the 230V mains Perform a full 60 second shot using water...

Page 22: ...1 DT 1600plus Lan 1601 DefenderTech Fog Generator Device Fog Genrator for safety applications They comply with the European Community Directives Low Voltage 2004 108 CE Electromagnetic Compatibily 200...

Page 23: ...ion directive C E E HAZARD IDENTIFICATIONS No specific danger can be found in the use of the effects PHYSICAL AND CHEMICAL PROPERTIES Physical state liquid Appearance and color liquid of transparent c...

Page 24: ...www defendertech eu info defendertech eu Tel 39 0721 1626113 Fax 39 0721 0731145...

Reviews: