MANAGEMENT OF MALFUNCTIONS:
The "malfunction" (opening status contact and video-acoustic signals) is generated by the system if any of
the following conditions should occur:
LIQUIDI_LEVEL_ALARM
:
occurs when the liquid level is below 20% of the tank.
When the estimated liquid in the tank end up, the system will allow a further 120 sec of firing (even if not
consecutive) and after this it will not allow others. It will be necessary to intervene to restore correct
operation, reloading the tank and setting the 100% level again using DipSwitch 4.
CARD_OVERHEATING_ALARM
: (
self-resetting) occurs when the inside of the appliance has exceeded the
maximum allowed temperature due to extreme weather conditions or bad installation (poor ventilation).
ABSENT_BATERY_ALARM
: (self-resetting) the appliance will continue to operate until the 230Vac power
supply will be present.
FAULTY_SONDE_ALARM
: occurs when the thermocouple is disconnected or damaged or if the reading is
incorrect, reset the error by operating the DipSwitch no. 5 if it persists, the appliance will not work until it
is replaced by the service DefenderTech.
LACK_NETWORK_ALARM
: (self-restoring) lack of electricity grid
BURNER_OVERHEATING_ALARM
: reset the error by operating on Dip Switch no. 5 if it persists contact the
DefenderTech service.
PUMP_FAILURE_ALARM
:
it occurs when the pump does not work or does not suck up liquid from the tank.
This signal does not affect the operation of the pumps, the machine will perform the firing procedure
regardless.
Reset the error by operating DipSwitch 5, if it persists contact the DefenderTech service.
Check if there is liquid in the tank, otherwise the hose, the pump or the solenoid valve are faulty, contact
the Service DefenderTech to be adviced on the action to be taken.
RESITENCE_BROKEN_ALARM
: it
occurs during the burner heating phase, if the temperature does not
increase in the expected quantity when the resistance is activated. Reset the error by operating DipSwitch
5, if it persists contact the DefenderTech service.
All faults can be verified through the monitoring sw DT-FogControl and
DT-MultiFogControl