Warranty and Liability Conditions 

1)

 

With this warranty, TEK GROUP S.r.l., based in 61025 Montelabbate (PU), Via Leonardo Da Vinci n. 8, 
guarantees the product from any defects in materials and manpowers, provided that the use complies with 
the conditions indicated in the manual, for the duration of 24 months from the date of purchase of the 
product resulting from a fiscally valid document. 
 

2)

 

This warranty does not apply to: (a) consumable parts - such as fluids and batteries - and components 
subject to wear; (b) damage resulting from an installation not carried out according to the instructions 
contained in the manual supplied with the product; (c) failures resulting from the use of non-original 
components and / or fluid; (d) damage due to repairs made by unauthorized personnel or by the Customer; 
(e) faults caused by incorrect power supply or connection; (f) defects resulting from normal wear or 
otherwise due to aging of the product; (g) damage caused by fortuitous events, lightnings, flooding, fire, 
incorrect ventilation or other causes not attributable to TEK GROUP S.r.l. 
 
 

3)

 

If during the warranty period the Customer finds defects of conformity of the product, then this will have to 
report their presence to the Producer on penalty of forfeiture within one week of discovery. 
 

4)

 

The Customer, provided that he has provided a timely description of the data contained in the 
documentation referred to in point (5), may be authorized by TEK GROUP S.r.l. to send the faulty or 
defective device for its repair. The Producer reserves the unconditional right to replace the defective parts 
with new or regenerated parts and equivalent to new ones in terms of functions, performances and 
reliability. 
 
 

5)

 

In order for the warranty to be operational, it must be kept together with a fiscally valid purchase document 
- such as an delivery note, invoice, receipt, showing the name of the seller, the date of purchase, the 
identification details of the product and the sale price. 
 

6)

 

This warranty will expire if the product is shipped unaccompanied by the aforesaid documentation, without 
a suitable packaging to protect it from shocks and vibrations and in case it is not shipped in its entirety 
(including cover and fluid tank). The wall fixing bracket is not included among the components that must be 
sent to the manufacturer for repair purposes. 
 
 

7)

 

The costs of uninstalling the defective device and reinstalling the repaired product or returned product, as 
well as the return shipping costs, are not included in this warranty. 

 

 

 

 

 

 

 

 

Summary of Contents for DT-800Lan

Page 1: ...Manual of installation and maintenance Fog Generators DEFENDERTECHDT 800Lan...

Page 2: ......

Page 3: ...e power supply of the appliance must be supplied through a special switch or plug in order to allow it to be switched off Danger of burns the components of the appliance are subject to heating do not...

Page 4: ...ct then this will have to report their presence to the Producer on penalty of forfeiture within one week of discovery 4 The Customer provided that he has provided a timely description of the data cont...

Page 5: ...igation to display The legislation provides for the obligation to post in the access route of the premises a notice that signals the presence of a Fog Generator Use the adhesive label supplied with th...

Page 6: ...adjustable up to 200 mm Nozzles extension lengh adjustable up to 500 mm Fog jet diversion kit passes through the wall behind the equipment Fog jet split and diversion kit 50 passes through the wall be...

Page 7: ...THE APPLIANCE Use 4 10 mm dowels fisher of the type suitable for the wall on which the machine will be installed If necessary it is possible to drill the bracket at any point of it adjacent to the wa...

Page 8: ...2 Place the appliance on the front of the bracket and let the four fins of the bracket penetrate the side slits of the appliance operation 1 3 Slide the appliance down 2nd operation 4 Using a 4mm Alle...

Page 9: ...Description DT 800Lan Control Card...

Page 10: ...te This contact can be used to assign other functions see p 14 special features STATE system status failure signal When the appliance is disarmed or switched off the Clean NA contact normally open wil...

Page 11: ...ording to the times programmed through the DipSwitch as shown in the table on page 13 If desired it is possible to change the contact activation mode to OPEN by turning ON the DipSwitch nr 3 Also ARM...

Page 12: ...vating this function the Fog2 input takes on the task of preventing accidental firing If a negative signal is present on FOG2 the shot will not be allowed If the signal arrives while the shot is in pr...

Page 13: ...X X X PUMP MODE CONTINUE X X X X X X X OFF X X IMPULSIVE DOUBLE THE SHOT TIME X X X X X X X ON X X RESISTANCE NUMBER 1 X X X X X X X X OFF OFF 2 X X X X X X X X ON OFF X X X X X X X X X X X X X X X X...

Page 14: ...ORK SIGNALING OFF OFF X X X X X X X X LACK OF NETWORK SIGNALED ON STATE RELAY ON ON X X X X X X X X LACK OF NETWORK NON SIGNALED ON STATE RELAY LIQUID LEVEL CONTROL OFF X OFF X X X X X X X LIQUID LEVE...

Page 15: ...nctions of the Menus 1 and 2 you will have to program them simultaneously starting from those of the menu 1 activate the DIP10 and then the DIP corresponding to the desired functions of the Menu2 DIP...

Page 16: ...PAUSE STATE FIXED ON THE APPLIANCE IS IN THE FORCED PAUSE STATE it will ignore every firing commands untili its end ONE FLASH FOR EVERY RIARMAMENT OF THE MACHINE FAILURE LED6 RED TURNED OFF NO ALLARM...

Page 17: ...on peaks especially if there are more Fogs Generators or there is only one that is turned on 24H SHOT MANAGEMENT The shot is inhibited when the appliance is unarmed the burner temperature is lower tha...

Page 18: ...DT MultiFogControl is responsible for monitoring simultaneously the operating status of several Fogs Generators even in different geographical sites Both software can be requested free of charge by m...

Page 19: ...s incorrect reset the error by operating the DipSwitch no 5 if it persists the appliance will not work until it is replaced by the service DefenderTech LACK_NETWORK_ALARM self restoring lack of electr...

Page 20: ...re the liquid level to the 100 acting on DipSwitch nr 4 TECHNICAL INSTALLATION Once the machine is connected to the mains activate the buffer battery connecting the flying cable to the respective free...

Page 21: ...following is prescribed to Replace the buffer batteries 2x12V 1 3 are wired in series Arm the appliance by measuring voltage and absorption on the 230V mains Perform a full 60 second shot using water...

Page 22: ...1 DT 1600plus Lan 1601 DefenderTech Fog Generator Device Fog Genrator for safety applications They comply with the European Community Directives Low Voltage 2004 108 CE Electromagnetic Compatibily 200...

Page 23: ...ion directive C E E HAZARD IDENTIFICATIONS No specific danger can be found in the use of the effects PHYSICAL AND CHEMICAL PROPERTIES Physical state liquid Appearance and color liquid of transparent c...

Page 24: ...www defendertech eu info defendertech eu Tel 39 0721 1626113 Fax 39 0721 0731145...

Reviews: