"BASE" DIP-SWITCH PROGRAMMING
FUNCTIONING
DIP1 DIP2 DIP3 DIP4 DIP5 DIP6 DIP7 DIP8 DIP9 DIP10
SHOT
T
IM
E
15 SEC
OFF
OFF
X
X
X
X
X
X
X
X
30 SEC
ON
OFF
X
X
X
X
X
X
X
X
45 SEC
OFF
ON
X
X
X
X
X
X
X
X
60 SEC
ON
ON
X
X
X
X
X
X
X
X
SHOT
IN
P
UT
NORMALLY OPEN (N.O.)
X
X
OFF
X
X
X
X
X
X
X
NORMALLY CLOSE (N.C.)
X
X
ON
X
X
X
X
X
X
X
LI
QU
ID
LIQUID RESET
X
X
X
ON-
OFF
X
X
X
X
X
X
FAI
LURE
RESET BLOCK FOR
FAILURE
X
X
X
X
ON-
OFF
X
X
X
X
X
FO
RC
ED
PA
U
SE
TI
M
E
5 MIN
X
X
X
X
X
OFF
OFF
X
X
X
10 MIN
X
X
X
X
X
ON
OFF
X
X
X
15 MIN
X
X
X
X
X
OFF
ON
X
X
X
20 MIN
X
X
X
X
X
ON
ON
X
X
X
PUM
P
M
ODE
CONTINUE
X
X
X
X
X
X
X
OFF
X
X
IMPULSIVE (DOUBLE THE
SHOT TIME)
X
X
X
X
X
X
X
ON
X
X
RE
SI
ST
AN
C
E
N
UM
B
ER
1
X
X
X
X
X
X
X
X
OFF
OFF
2
X
X
X
X
X
X
X
X
ON
OFF
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Basic SET-UP of the Fog Generator
Shot time: 60 seconds.
Forced pause after firing:
for the next 10 minutes the unit will ignore further firing commands
DIP-Switch configuration ON 1-2-6-9
ARM and FOG, N.O. (Normally Open)
Number of Resistors used
: by default two but it is possible to limit its use to only one, in that case the
appliance will take twice the time to reach the operating temperature, but the quantity of fog delivered will
not change.
The above parameters can however be modified using DIP switches according to the table above.