FUNCTIONAL DESCRIPTION IN SHORT
BURNER “INTELLIGENT” MANAGEMENT:
The burner is activated only when the appliance is ARMED and this can happen only by activating the
"ARM" input on the CPU board or by using the "Preheating" special function which maintains the operating
temperature at 50% during the disarmament phase (this to speed up the reset phase especially if the
number of resistances has been halved for electric charge issues (DIP9)).
The 100% burner ignition will be inhibited if the time block is active and it is programmable through the Sw
DT-FogControl (checkout the instruction manual).
By ARMING the appliance (ARM), the resistances are activated in increments of 5 seconds.
The resistences will only turn off after reaching 100% of the operating temperature
When the temperature drops below 97%, only one resistence will be reactivated, to reduce current
absorption peaks especially if there are more Fogs Generators or there is only one that is turned on
24H.
SHOT MANAGEMENT:
The shot is inhibited when:
- the appliance is unarmed.
- the burner temperature is lower than that needed to dispense dry and quality fog.
- The forced pause phase is active (used to avoid excessive shots in a room already
saturated with fog).
- The "Safe Firing" function is active.
- Liquid level is ZERO.
After the shot, of configurable duration (60 seconds by deafult) a 10 seconds wash will follow. This
phase consists in the activation of a selenoid valve that introduce air into the burner to clean it at
the end of the shot.
At the end of the shot the system will ignore any further firing request for the set standby time
(forced pause).
At any time the firing phase can be interrupted, DISARMING the appliance; however, also in this
case, the wash cycle will still be executed.
ETHERNET NETWORK CONNECTIVITY:
The DT-x00Lan series devices have been designed to be monitored and programmed remotely using the
DEFENDERTECH "DT-FogControl" and "DT-MultiFogControl" software.