Entry 1
- The system uses this mer to allow the user me to access the keypad and disarm the par
on 1.
(Can be set
from 000 to 255 sec)
Entry 2
- The system uses this mer to allow the user me to access the keypad and disarm the par
on 2.
(Can be set
from 000 to 255 sec)
Exit 1
- This mer controls the delay between the user ini a ng the exit procedure for the par
on 1.
(Can be set
from 000 to 255 sec)
Exit 2
- This mer controls the delay between the user ini a ng the exit procedure for the par
on 2.
(Can be set
from 000 to 255 sec)
Bell Time
- This mer controls the dura on of the bell output a er an alarm has accurred in the selected par
on.
(Can be set
from 000 to 255 minute)
Fast respond
- If a zone is programmed with the ‘ fast respond’ a ribute, the zone respond will be controlled by the dura on
of this mer.
(Can be set
from 001 to 255 x 1.6ms)
Slow respond
- If a zone is programmed with the ‘slow respond’ a ribute, the zone respond will be controlled by the dura on
of this mer.
(Can be set
from 001 to 255 x 1.6ms)
Intelligent counter
- The zone is enable for the intelligent zone will only cause alarm if the counter exceed.
Intelligent reset
Ɵ
me
- The zone is enable for the intelligent zone will only cause alarm if the intelligent counter exceed in the
reset me.
Home Automa
Ɵ
on
- Is use for connec on to household appliances.
Keypad Lock Digit
- The keypad will auto lock if key in the wrong password.
(Can be set
from 000 to 255 me)
Keypad lock
Ɵ
me
- The keypad will auto unlock when the lock me exceed.
(Can be set
from 000 to 255 sec)
Communicator dialing
Ɵ
me
- The me to wait for the user to answer during personal repor ng.
Communicator idle
Ɵ
me
- Time to wait for key press before auto hang up during personal repor ng.
Communicator dial loop
- Number of me to dial on each telephone number.
Answer ring
- Number of ring required in order to answer the incoming call.
(Can be set
from 000 to 255 ring)
Communicator password error auto hang up
- Number of error password digit is allowed to key in before communicator auto
hang up.
CMS periodic report
- This mer controls the interval me of the CMS periodic report.
Technical Data
Time Se
ƫ
ng
Entry 1
Entry 2
Exit 1
Exit 2
Bell Time
Fast respond
Slow respond
Intelligent counter 1
Intelligent counter 2
Intelligent reset
Ɵ
mer 1
Intelligent reset
Ɵ
mer 2
Home Automa
Ɵ
on 1
Home Automa
Ɵ
on 2
Keypad lock digit
Keypad lock
Ɵ
me
Communicator dialing
Ɵ
me
Communicator idle
Ɵ
me
Communicator dial loop
Communicator password error auto hang up
CMS periodic report
Answer ring
Address
40
41
42
43
44
45
46
47
48
49
50
51
52
55
56
59
60
61
62
024
hour
times
ring
times
sec
sec
sec
times
-
-
minute
minute
times
times
ms
ms
minute
sec
sec
sec
sec
Unit
012
008
010
040
040
060
012
-
-
010
030
003
002
008
015
005
120
120
040
040
Default Value
58
57
b. Open the browser login to DSA. Type in
http://defender:8088
. Login page will show as below.
Figure 3.0 Login Page
c. Key in the Master or User password (max 4 digits numeric).
d. Func
Ɵ
onality of DSA
• ARM – to arm the home alarm panel
• DISARM – to disarm the home alarm panel
• BYPASS – to set or clear the zone bypass
e. Con
fi
gura
Ɵ
on of DSA (only master authen
Ɵ
cate)
• Zone se ng – to de
fi
ne zone loca on and IP Camera Link for each zone.
• PGM se ng – auto mer Arm/Disarm and auto mer On/O
ff
PGM (24 hour format).
• Network se ng – to set the DSA network con
fi
gura on in Dynamic (IP address assign by router) or Sta c
(IP address assign by user).
• User password se ng – change the user’s login password (only 4 digits acceptable).
• Log status – to indicate who and what ac vi es done on DSA.
f. The status of home alarm panel status will shown as below a
Ō
er login.
USER LOGIN
Password :