+V & -V - connect to Dc 12 power supply.
1 S - Connect 1 S to zone 8
2 S - Connect 2 S to pin number 2
Com - Connect com to pin number 1

(1 S is use for panic bu on)
(2 S is use for Arm and Disarm System)

REMOTE CONTROL CONNECTION LAYOUT

KEYPAD CONNECTION (1) LAYOUT KEYPAD CONNECTION (2) LAYOUT

Connect the 8G with Dt
Connect the SCK with CIK
Connect the Gnd with Gnd 
Connect the 12V with 12V

ZONE PROGRAMMING

Default Zone Type

1

2

3

4

5

6

7

8

Zone Type

Address

Zone

Delay

10

11

13

14

15

16

18

19

20

21

22

23

25

26

Internal

Instant

24 Hour

Fire

Silent

Zone Respond

Intelligent Zone 1

Intelligent Zone 2

Zone Par

ƟƟ

on1

Zone Par

ƟƟ

on2

Auto Reset Zone

Par

ƟƟ

on 1 user

Par

ƟƟ

on 2 user

(         is default se

ƫ

ng)

connect to 
zone 8

b. PGM se

ƫ

ng (

fi

gure 6.0)

• Timer Arm/Disarm – set the auto  mer arm or disarm the par

on 1 or par

on 2 alarm panel (24 

hour format).
• Timer PGM – set the auto  mer on or o

 light (24 hour format). If PGM are not 64, 65, and 66, cannot 

auto  mer func on. Refer to installer manual for PGM de

fi

ni on.

c. Network se

ƫ

ng (

fi

gure 7.0)

• For Dynamic DHCP,  ck the Enable DHCP.
• For Sta c, un- ck the Enable DHCP (refer to step 4.0 for detail).

Partition 1

Partition 2

ARM

DISARM

ENABLE

ARM

DISARM

ENABLE

Timer 1

Timer 2

On

Off

On

Off

24 Hr Format

Light 1

Light 2

Note

To use the auto 

mer please 

perform PGM 

se ng

This page allows the configuration of the board’s network settings.

CAUTION: Incorrect settings may cause the board to lose network connectivity. Recovery

options will be provided on the next page.

Enter the new settings for the board below:

Figure 6.0 PGM Se

ƫ

ng

Figure 6.0 PGM Se

ƫ

ng

Summary of Contents for 3.0 Voice Plus

Page 1: ...Voice Plus SpecificaƟons are subject to change without noƟce Defender is a registered trademark of defender Co Ltd Other brands and product names are trademarks of their respecƟve holders Copyright 2009 All rights reserved Defender Co Ltd ...

Page 2: ...tructions in the literature accompanying the appliance INFORMATION This equipment has been tested and found to comply with limits of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated WARNING Do not changes or modify any parts or component used and approved by the manufacturer WARNING To prevent electric shock and ri...

Page 3: ...m to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmentally safe recy...

Page 4: ...sing in high temperature condi ons PrecauƟons Do not install system under extreme temperatme condi ons or in high humidity environment DescripƟon Zone 1 2 3 4 5 6 7 8 Entrance Internal Delay Instant 24 hour Timer Entry Time Exit Time Bell Cut Off Time Telephone Number of ring before answer Each number well be dial 1 2 3 4 System InstallaƟon InformaƟon ...

Page 5: ...ge due to causes beyond the control such as excessive voltage mechanical shock or water damage damage caused by unauthorized aƩachment alteraƟons modificaƟons or foreign objects damage caused by peripherals defects caused by failure to provide a suitable installaƟon environment for the products damage caused by use of the products for purposes other that those for which it was designed InternaƟona...

Page 6: ...d this manual carefully and have you installer instruct you on system operaƟon and on which features have been implemented in your system About Your Security System WARNING Remember The system requires minimum maintenance This system is an advanced security system it does not offer guaranteed protection against burglary fire or other emergency Whether commercial or residential Intruders may gain a...

Page 7: ...ystem programming menu Press 40 Enter the entry Ɵmer Press to save exit programming menu To Set The Exit Time Press o follow by installer code to access the system programming menu Press 42 Enter the exit Ɵmer Press to save exit programming menu To Set The Silent Zone Press o follow by installer code to access the system programming menu Press 16 Enter the zone number Press 2 Ɵme to save exit prog...

Page 8: ...xxxx xxxx 4 digit To Add The Phone Number The system must be disarm Press 7 follow by master code 4 digit Press user number x maximum can set up to 4 user Press the user phone number Press a er finish to save exit Programming menu To Delete The Phone Number Press 7 follow by master code 4 digit Press user number x which want to delete Press to save exit Programming menu To Turn On Off The Chime Mod...

Page 9: ...is no assign by Router example refer to figure 10 3 192 168 1 3 was assign by Router if user want to use another IP address as staƟc 192 168 1 10 Go to Network ConfiguraƟon figure 10 0 un Ɵck the ENABLE DHCP and change the IP Address to 192 168 1 10 and click the Save Config buƩon Reboot message will shown figure 10 1 PS Exit close the browser without click the link hƩp DEFENDER 8088 Login to Rout...

Page 10: ...re 10 2 PS Please do not click the link first hƩp DEFENDER 8088 Figure 10 1 Reboot Login to Router s configuraƟon select DSA Mac address and IP address and change the status to staƟc Then click save the new configuraƟon info was shown in figure 10 3 This page allows the configuration of the board s network settings CAUTION Incorrect settings may cause the board to lose network connectivity Recover...

Page 11: ...igure 9 0 Reload buƩon for reload the latest informaƟon Maximum show 80 events aŌer 80 events the next events will show at first locaƟon Figure 9 0 Log Status Date Time 11 10 2010 10 19 11 10 2010 10 19 11 10 2010 10 19 11 10 2010 10 19 11 10 2010 10 19 11 10 2010 10 19 11 10 2010 10 09 11 10 2010 10 09 11 10 2010 10 09 11 10 2010 10 09 11 10 2010 10 01 11 10 2010 09 25 11 10 2010 09 21 11 10 2010...

Page 12: ...user ParƟƟon 2 user is default seƫng connect to zone 8 b PGM seƫng figure 6 0 Timer Arm Disarm set the auto mer arm or disarm the par on 1 or par on 2 alarm panel 24 hour format Timer PGM set the auto mer on or off light 24 hour format If PGM are not 64 65 and 66 cannot auto mer func on Refer to installer manual for PGM defini on c Network seƫng figure 7 0 For Dynamic DHCP ck the Enable DHCP For St...

Page 13: ...el will report Arm Disarm to the centre Off The panel will not report Arm Disarm to the centre Report AC Fail On The panel will report AC Fail to the centre Off The panel will not report AC Fail to the centre Report Enter Exit Programming Mode On The panel will report Enter Exit programming to the centre Off The panel will not report Enter Exit programming to the centre Report Telephone Line Fault On...

Page 14: ...arm using H or A key Off Disable arm using H or A key BuƩon P On Enable using bu on P for panic bu on Off Disable using panic bu on Remote Control On The panel will Enable remote control Off Disable remote control Bell Squawk On The panel siren will pulsed once_when the system is arm pulsed twice when the system is disarm Off The siren will behaves normally on arm and disarm Zone 4 Enable Fix line Zon...

Page 15: ... auto hang up during personal repor ng Communicator dial loop Number of me to dial on each telephone number Answer ring Number of ring required in order to answer the incoming call Can be set from 000 to 255 ring Communicator password error auto hang up Number of error password digit is allowed to key in before communicator auto hang up CMS periodic report This mer controls the interval me of the ...

Page 16: ...Code Reset panel Address 70 71 72 73 76 98 99 1397 0000 0000 Default Value System System Time System Date System Year Auto Arm Par on 1 Auto Disarm Par on 1 Auto Arm Par on 2 Auto Disarm Par on 2 Night Mode begin me Night Mode end me Control Timer 1 on Control Timer 2 on Control Timer 1 off Control Timer 2 off Auto Off mer Address 30 31 32 33 34 35 36 37 38 43 Minute 42 41 40 39 HHMM HHMM HHMM HHMM H...

Page 17: ...Open Without Auto Off Feature Zone Open With Auto Off Feature Control follow Timer 1 Zone Open with Auto Off Feature during Night Mode Zone Open without Auto Off Feature during Night Mode Control follow Timer 2 Control follow Timer 1 2 Ac vate during away arm without auto off feature Ac vate during away arm with auto off feature Ac vate during away arm with auto off feature during Night Mode Ac vate duri...