4.2.2.
Anchorage fittings for roof mounting
The roof anchors are not included in the roof-surface
installation set and must be ordered separately.
CAUTION
Before installation, make sure that the framework is solid
and strong enough to comply with the static requirements.
There are different types of roof anchor available:
4
Aluminium roof anchors for assembly independent of the
chevrons.
4
Rafter-mounted anchors.
4
Hooks to be fitted to the roof covering.
In the first case, additional mounting battens have to be added to the
roof structure. In order to fit the mounting battens to the framework of
a finished roof, the roof tiles covering the entire length of the mounting
battens have to be moved out of the way. The roof anchors are then
located on the battens and fixed.
With the rafter-mounted type, only individual tiles above the fixing
points on the rafters have to be removed. The roof anchors are
screwed to the rafters thus exposed. Afterwards, the tiles are replaced
and the roof is immediately waterproof again. The installation of the
panel-mounting system can start.
If installing on metal rooves, the roof anchors must be ordered from
the manufacturer of the roof system concerned.
The hoses of the solar-panel connection sets can be passed through
the roof by feeding them through a vented roof tile.
n
Aluminium roof anchor for long-stringed gutter tile
EG 311 (4 pieces)
EG 312 (6 pieces)
On tiled rooves, additional mounting battens are added to the roof
substructure.
Charateristics of the assembly plates:
4
Cross section: 30 x 90 mm
4
Length: Width of the bank of solar collectors
4
The ends must rest on a chevron
The roof anchors are fixed to these assembly planks (
assembly
independent of the chevrons
).
n
Stainless steel roof anchor for long-stringed gutter tile
EG 313 (4 pieces)
EG 314 (6 pieces)
These roof anchors are attached directly to the roof rafters (
rafter-
mounted
anchors).
M001741-A
M001742-A
<100
NEO 2.1 / SUN 211
4. Installation
05/10/09 - 300020210-001-B
12
Summary of Contents for NEO 2.1
Page 4: ...3 05 10 09 300020210 001 B ...
Page 20: ...M001777 A I M001778 A 4 Installation NEO 2 1 SUN 211 19 05 10 09 300020210 001 B ...
Page 26: ...3 4 5 M001766 A 4 Installation NEO 2 1 SUN 211 25 05 10 09 300020210 001 B ...
Page 29: ...n Solar Panel Connection M001769 A NEO 2 1 SUN 211 4 Installation 05 10 09 300020210 001 B 28 ...
Page 32: ...2 3 M001784 A 4 Installation NEO 2 1 SUN 211 31 05 10 09 300020210 001 B ...
Page 35: ...n Solar Panel Connection M001787 A NEO 2 1 SUN 211 4 Installation 05 10 09 300020210 001 B 34 ...