6 Checking and maintenance
6.1
General instructions
CAUTION
4
Maintenance operations must be done by a qualified
professional.
4
An annual inspection is compulsory.
4
Only original spare parts must be used.
4
Protection of the environment: Place a container of
sufficient volume under the drain pipe and the valve
discharge pipe.
4
Check the solar collectors and their fastenings.
4
Check that the hydraulic connections are leak tight.
4
The hydraulic pressure must be a minimum of 2 bars
4
Check that the sensors are operating correctly.
4
Check the safety devices (particularly the valve or safety unit),
referring to the instructions provided with these components.
4
Check the antifreeze power of the heat transporting fluid
(Minimum -20 °C).
4
Check the pH of the heat transporting fluid; it should be between
7 and 8.
4
Clean the surface of the solar collectors using a soft, damp cloth.
4
Check that the gaskets and connections are in good condition.
4
Check that the insulation is in good condition (no mechanical
deterioration or damage caused by the pecking of birds or UV).
6. Checking and maintenance
NEO 2.1 / SUN 211
41
05/10/09 - 300020210-001-B
Summary of Contents for NEO 2.1
Page 4: ...3 05 10 09 300020210 001 B ...
Page 20: ...M001777 A I M001778 A 4 Installation NEO 2 1 SUN 211 19 05 10 09 300020210 001 B ...
Page 26: ...3 4 5 M001766 A 4 Installation NEO 2 1 SUN 211 25 05 10 09 300020210 001 B ...
Page 29: ...n Solar Panel Connection M001769 A NEO 2 1 SUN 211 4 Installation 05 10 09 300020210 001 B 28 ...
Page 32: ...2 3 M001784 A 4 Installation NEO 2 1 SUN 211 31 05 10 09 300020210 001 B ...
Page 35: ...n Solar Panel Connection M001787 A NEO 2 1 SUN 211 4 Installation 05 10 09 300020210 001 B 34 ...