Code
Description
Checking / solution
The middle domestic hot water temperature sensor
is open.
Bad connection
Check whether the sensor is connected.
Check the connection and the connectors.
Check that the sensor has been fitted properly.
Sensor failure
Check the Ohmic value of the sensor.
Replace the sensor if necessary.
The middle domestic hot water temperature sensor
is in short circuit.
Bad connection
Check whether the sensor is connected.
Check the connection and the connectors.
Check that the sensor has been fitted properly.
Sensor failure
Check the Ohmic value of the sensor.
Replace the sensor if necessary.
The top domestic hot water temperature sensor is
open.
Bad connection
Check whether the sensor is connected.
Check the connection and the connectors.
Check that the sensor has been fitted properly.
Sensor failure
Check the Ohmic value of the sensor.
Replace the sensor if necessary.
The top domestic hot water temperature sensor is
in short circuit.
Bad connection
Check whether the sensor is connected.
Check the connection and the connectors.
Check that the sensor has been fitted properly.
Sensor failure
Check the Ohmic value of the sensor.
Replace the sensor if necessary.
The bottom domestic hot water temperature sen
sor is open.
Bad connection
Check whether the sensor is connected.
Check the connection and the connectors.
Check that the sensor has been fitted properly.
Sensor failure
Check the Ohmic value of the sensor.
Replace the sensor if necessary.
The bottom domestic hot water temperature sen
sor is in short circuit.
Bad connection
Check whether the sensor is connected.
Check the connection and the connectors.
Check that the sensor has been fitted properly.
Sensor failure
Check the Ohmic value of the sensor.
Replace the sensor if necessary.
Filter servicing date passed.
Replace the filter.
The control module batteries do not have sufficient
charge.
Replace the batteries.
No radio communication between the water heater
and the control module.
Check that the water heater is receiving power.
Remove the batteries from the control module,
then refit them.
Test the radio connection (Radio test menu).
Pairing of the control module and the water heater
not possible.
Force pairing from the control module or perform
manual pairing.
9 Troubleshooting
66
TWH 200 EV
EN-7602142 - v11 - 24042019