Tab.6
Display
Domestic hot water pro
duction
Description
MW-C003487-03
Heat pump
The 2 sections of the tank flash simultaneously when domestic hot water produc
tion is provided by the heat pump
MW-C003484-03
Electrical back-up
The right-hand section of the tank flashes when domestic hot water production is
provided by the electrical back-up
MW-C003486-03
Heat pump + Electrical
back-up
The 2 sections of the tank flash in turn when domestic hot water production is
provided by the heat pump and the electrical back-up
Indicator for the available volume of water
During production of domestic hot water, the display indicates the number
of baths available and the filling level for the tank (available quantity of hot
water).
The number of baths is calculated based on a domestic hot water
temperature of 40°C.
The tank is filled based on the set point temperature.
Set the parameter
according to the volume of water required for a
bath.
For more information, see
Modifying the installer parameters, page 51
6.1.3
Browsing in the menus
1. Press the MENU key once.
The SEtP 1 menu is displayed (Temperature measurement).
2. Use the and keys to scroll through the menus (see table
below).
3. To go into the selected menu, press the MODE key ( ).
4. To return to the previous display, press the MENU key.
Fig.33
C003493-B
1
4
3
4
1
2
Fig.34
C003203-E
1x
3
1
4
3
4
1
2
MENU
MODE
Fig.35
M002843-B
1
4
3
4
1
2
MENU
MODE
6 Commissioning
46
TWH 200 EV
EN-7602142 - v11 - 24042019