6.3.2
Pairing the control module and the tank
Important
Only affects appliances with a control module which has been
installed in radio mode.
Powering on for the first time
Important
When powering on for the first time, the control module will
automatically pair with the water heater control system PCB.
If there are any issues when pairing, perform a forced pairing procedure.
See
Forcing pairing from the control module section.
Forcing pairing from the control module
1. Simultaneously press the and MODE keys.
The Pair SEt menu is displayed.
2. Press the MODE key to confirm to start pairing.
3. If pairing is successful, the control module displays InIt.
Forcing manual pairing
1. Remove the batteries from the control module.
2. Connect the control module with a wire to the tank control system
PCB.
3. Switch on the power to the tank.
4. Press the key for 5 seconds.
The rSt HMi menu is displayed.
5. Press the MODE ( ) key.
6. Switch off the power to the tank.
7. Perform the radio connection procedure for the control module.
For more information, see
Wire connection, page 36
6.4
Checks and settings after commissioning
1. Check the tightness of the connections.
2. Check the temperature on the 3 domestic hot water temperature
sensors to ensure that the appliance is working correctly.
If the readout values are incorrect, check the positioning of the
sensors in the sensor tube.
Fig.36
C004779-B
1
4
3
4
1
2
MENU
MODE
Fig.37
C004780-B
1
4
3
4
1
2
MENU
MODE
Fig.38
C004781-B
1
4
3
4
1
2
MENU
MODE
6 Commissioning
48
TWH 200 EV
EN-7602142 - v11 - 24042019