5.8
Condensate discharge
1. Fit a siphon into the condensate discharge duct.
Caution
If no siphon is fitted, there is a risk of problems with the discharge
of condensates when the compressor is running.
2. Attach the run-off collector.
5.9
Fitting and connecting the control module
The regulator control module is not fitted on the water heater when
delivered, so that it can be installed in one of the living areas, to make it
easier to use.
This control module can be installed remotely with a wire or radio
connection, or integrated.
5.9.1
Radio connection (installation strongly recommended)
Fitting the control module
Warning
Choose a location which enables good radio reception.
See
To test the quality of the radio reception, see the section: “Radio
test menu”.
Important
The quality of the radio reception may be affected by the
construction materials used within the home (thickness of the
walls or floor tiles, types of materials used).
Placing a hand in front of the control module may affect the
reception.
Fig.19
M002834-E
1
min. 200
5 Installation
34
TWH 200 EV
EN-7602142 - v11 - 24042019