Important
This configuration may include a maximum of:
3 bathrooms
3 WCs
1 kitchen
4.3.2
Direct connection to the thermodynamic water heater
In this configuration, the air duct vacuum pressure set point (parameter
) must be set to 1 (= 100 Pa).
1 Sanitary extractor fan outlets, Ø 80 mm (bathroom / WC)
2 Kitchen extractor fan outlet, Ø 125 mm
3 Thermodynamic water heater
4 Roof-mounted discharge
5 Duct (insulated if outside of the heated area)
6 160/125 reduction sleeve
Important
This configuration may include a maximum of:
1 bathroom
1 WC
1 kitchen
4.3.3
Multi-duct network with collector
In this configuration, the air duct vacuum pressure set point (parameter
) must be set to 2 (= 125 Pa).
Fig.4
C004496-B
1
1
6
2
Ø125
Ø160
Ø80
Ø80
4
5
5
5
5
3
4 Description of the product
18
TWH 200 EV
EN-7602142 - v11 - 24042019