2. Flush the installation with at least 3 times the volume of water
contained in the central heating system (until the water runs clear and
shows no impurities).
For more information, see
Flushing an existing installation
Before filling the heating installation, it is essential to remove any sludge
deposits which have accumulated in the heating circuit over the years.
1. Remove any sludge from the installation.
2. Flush the installation with at least 3 times the volume of water
contained in the central heating system (until the water runs clear and
shows no impurities).
For more information, see
7.8.2
Filling the siphon
1. Clean the siphon.
2. Completely fill the siphon until it overflows.
Danger
Fill the siphon to the top. If the siphon is empty, there is a danger
of poisoning by combustion products.
For more information, see
7.9
Completing installation
1. Reconnect the earth wire and put the front panel back in place.
2. Discard the various packaging items.
3. Affix the data plate found in the instructions bag to a visible part of the
boiler.
For more information, see
7 Installation
58