General
Certification
CE EMC, FCC CLASS A, CSA
Electrical
Input Voltage
18 to 30VAC; 24VAC nominal, 24VDC
Power Requirement
24VAC/VDC 1A
Power Consumption
Maximum 20W
Alarm Output
4 Normal relays 24VDC/1A Max. (selectable NC/NO)
Alarm Input
8 Normal dry contact (selectable NC/NO)
Control
RS-485/422 baud rate: 2400~230k bps (default: 9600bps)
Access Time
0.75 second maximum preset recall time
ID (Camera Address)
999
Mechanical
Dimension
See Figure 10
Weight Approx
1.2
kg
Pan Angle
360
°
continuous rotation
0.1
°
to 90
°
/sec. (proportional to zoom)
Speed
Preset Speed: 380
°
/sec
Repeatability
0.2
°
Flip
Rotate 180
°
at bottom of tilt
Autoscan
8 auto scan include vector scan
Preset Position
240 positions with camera status (16-character title)
Tour
8 tours
Pattern
Four patterns, 240 second
On-Screen Display
Displays camera ID and area name on screen
Environment
Operating temperature
0
°
C to 50
°
C (32
°
F to 122
°
F)
Operating humidity
0 to 90%RH (non-condensing)
Storage temperature
-20
°
C to 60
°
C (4
°
F to 140
°
F)
Specifications are subject to change without notice.
Figure 10 – Dimension