6
2.5 Setting Dome Camera Protocol
If a dome camera is to be installed with a Dedicated Micros KBS3 keyboard, select the switch as
the same as the Dedicated Micros DVR.
Consult service personnel if a dome camera is installed with device other than a keyboard
controller.
S/W
On
Off
F
UNCTION
D1 S4-1
Enable
Disable
Alarm
D2 S4-2
PAL NTSC
NTSC/PAL
D3 S4-3
ENDLESS
Pan
mode
D4 S4-4
RS-422
RS-485 RS-422/RS-485
D5
D6
D7
S5-1 S5-2 S5-3
P
ROTOCOL
Off Off Off
F2,F2E,P,D,E & Ph Protocol
(Default)
Off Off On
Reserved
Off On Off
S
422
Off On On
Reserved
On Off Off
V
Protocol
On Off On
Reserved
On On Off
D
Color
On On On
Reserved
D8
D9
D10
S5-4
S6-1 S6-2
B
AUD
R
ATE
Off Off Off
2400
bps
Off
Off
On
4800 bps
Off On Off
9600
bps
(Default)
Off On On
19200
bps
On Off Off
38400
bps
On Off On
57600
bps
On On Off
115200
bps
On On On
230400
bps
D11
D12
S6-3
S6-4
C
AMERA
Off Off Default
cameras
(Default)
Off On
Reserved
On Off
Reserved
On On
Reserved
Dedicated Micros DVR
Defaults(9600bps)
D1
D2
D3
D4
D5
D6
D7
D8
D9
D10
D11
D12
ON
ON
OFF
OFF OFF OFF OFF OFF OFF OFF OFF
OFF OFF OFF
Figure 6 – Protocol Selection Switches
Camera
Protocol
Alarm
1
2
3
4
S6
S5
S4
Baud rate
NTSC/PAL
RS-485
1
2
3
4
1
2
3
4
RS-422/
D
1
D
2
D
3
D
4
D
5
D
6
D
7
D
8
D
9
D
1
2
D
1
0
D
1
1
NTSC
PAL
on
on
S4
S4
Note: When you use the
Pelco-P protocol with 4800bps
in the DVR, you should
change the baud rate to 4800
bps of the dome.