4.1.1 Arrangement
To demonstrate this use case the following setup is recommended:
Mount the 3 Anchors at the same height
Note: Differences in heights will result in reduced accuracy of location
Mount the 3 Anchors high enough where there is good Line-of-Sight (LOS) with no
obstructions between them e.g. mounting 2-3 m high would ensure they are above
people’s heads which will help avoid interference.
Mount the 3 Anchors to create a triangle
Ensure the antennas are >15 cm away from the nearest wall or any other objects
Connect the PC to one of the Anchors
Power the other 2 Anchors and the Tag using an external USB battery (or other
method)
Figure 17: Tracking Use Case: Arrangement
4.2 Geo-Fencing Use Case
For evaluating the tracking use case the system is configured as:
1 Anchor
3 Tags
In this case example below: Channel 2, 110 kbps is selected as the operating mode.
The Anchor is configured as shown below.
Figure 18: Geo-Fencing Use Case: Example Anchor Settings