G E K O
20
PAR
.
PROCEDURE
SETT
ABLE V
ALUES
PROGRAMMING PROCEDURES
Positioning of operator 1
Positioning of operator 2
Memorization of the motors’ stroke
Deletion of transmitters
Transmitters memorizing
Search and deletion of a transmitter
Loading of standard parameters: the list is up dated with factory settings
DEA_NET net learning (not available at the moment)
PAR
.
PARAMETER DESCRIPTION
SETT
ABLE V
ALUES
DEF
A
UL
T V
ALUES
(for different standards
of installation)
Swing gate
INPUTS CONFIGURATION PARAMETERS
INPUT_3 selectioning input type
•
000:
IN3
type=free
contact
•
001:
IN3
type=constant
resistance
8K2
(free contact)
INPUT_1 operating selection
•
000:
NONE
(unused
parameter)
•
001:
ST
ART
(start)
•
002:
PED
. (pedestrian)
•
003:
OPEN
(separated
open)
•
004:
CL
OSE
(separated
close)
•
005:
OPEN_PM
(man
present
open)
•
006:
CL
OSE_PM
(man
present
close)
•
007:
PHO
TO
(photocell)
•
008:
SAFETY
(safety
rib)
•
009:
ST
OP
(lock)
•
010:
FCA1
(opening
limit
switches
Mot1)
•
011:
FCA2
(opening
limit
switchtes
Mot2)
•
012:
FCC1
(closing
limit
switches
Mot1)
•
013:
FCC2
(closing
limit
switches
Mot2)
IN1
(ST
ART)
INPUT_2 operating selection
IN2
(PHO
TO)
INPUT_3 operating selection
IN3
(ST
OP)
INPUT_4 operating selection
IN4
(PED)
INPUT_5 operating selection
IN5
(NONE)
Allocation of CHANNEL 1 of remotes
•
000:
NONE
(unused
parameter)
•
001:
ST
ART
(start)
•
002:
PEDESTRIAN
(pedestrian)
•
003:
OPEN
(separated
open)
•
004:
CL
OSED
(separated
close)
•
005:
OPEN_PM
(man
present
open)
•
006:
CL
OSED_PM
(man
present
close)
CH1
(ST
ART)
Allocation of CHANNEL 2 of remotes
CH2
(NONE)
Allocation of CHANNEL 3 of remotes
CH3
(NONE)
Allocation of CHANNEL 4 of remotes
CH4
(NONE)
Selection of type of remotes
•
000:
HCS
fix
-code
•
001:
HCS
rolling
-code
•
002:
Dip
-switch
OPERATORS
CONFIGURATION
PARAMETERS
Selectioning operators number
•
001:
one
operator
•
002:
two
operators
Selected work with or without encoders.
CA
UTION
: Remember to correctly set the jumpers J5 and J9 (see table 1)
W
ARNING
: J5, J9 and P021 must be set correctly before performing the procedure for programming
•
000:
motors
with
encoder
•
001:
engines
without
encoder