PSXX Manual Rev: A Software Rev: F
12
J7-5 & J7-6 Output TBD
J8
Used to program software updates. Do not make any connections
J10-1 [+] and J10-2 [-]
output is on any time that D12 (GREEN) is on. This output should
ONLY be connected to an isolated LED. Use an optical coupler interface for all other
uses.
J11-1 [+] and J1 1-2 [-]
output is on any time that D7 (GREEN) is on. This output should
ONLY be connected to an isolated LED. Use an optical coupler interface for all other
uses.
G. PSXX Accessory Addresses
See Section K: DCC System Sequential Programming Instructions for Setting
Address and Programming CV’s
The easiest way to address a PSXX circuit breaker is at your workbench. The
PSXX’s addresses are SET by moving the program jumper as described below
and issuing an accessory command like operating an accessory by using your
DCC Throttle.
For all systems, whenever you enter an address or CV value, you should see D17 flash. This indicates
the PSXX has received the information, stored it, and verified the stored data match the data you sent.
There are three [3] accessory addresses used by the PSXX. The third address is
reserved for future functions.