DazeTechnology DazeBox C Installation Manual Download Page 8

1.4. Abbreviations

Abbreviation

Definition

AC

Alternating current

DC

Direct current

EMC

Electromagnetic compatibility

EV

Electric Vehicle

EVSE

Electric Vehicle Supply Equipment

PE

Protective earthing

1P

Single-phase

3P

Three-phase

PM

Power Management

1.5. Terminology

Term

Definition

Installer

External contractor contracted by the owner to carry out
technical, civil engineering and electrical installation work

Owner

Legal owner of the wallbox

User

Owner of an electric vehicle (EV) using the EVSE device
to charge the EV

Local regulations

All regulations applicable to the EVSE device during its
entire life cycle. Local regulations include national

8

Summary of Contents for DazeBox C

Page 1: ...DAZEBOXC Installation Manual...

Page 2: ...plied with the device to the Customer DazeTechnology shall not be held liable for any damage that may directly or indirectly be caused to persons property or animals due to failure to comply with all...

Page 3: ...3...

Page 4: ...3 6 Daze App Matching 16 4 INSTALLATION 17 4 1 Choice of the installation site 17 4 2 Packaging 19 4 3 Transport and preliminary check 19 4 4 Protection and power supply of the charging station 20 4...

Page 5: ...OF USE 50 6 PRODUCT CARE 52 7 VISUAL SIGNALS 54 7 1 Waiting Power Management status on three phase system 55 7 2 Internal temperature management 56 8 OUT OF SERVICE 57 8 1 Dismantle 57 8 2 Storage 59...

Page 6: ...overs the installation use and care of the wallbox The most recent and up to date version of this manual can be found on the website The original instructions in this document are in Italian ITA All o...

Page 7: ...eful documentation See the other documents on the site by framing the QR code DazeBox C Installation Manual EC Declaration of Conformity Drilling template Dynamic Power Management Manual 1 3 Used symb...

Page 8: ...phase PM Power Management 1 5 Terminology Term Definition Installer External contractor contracted by the owner to carry out technical civil engineering and electrical installation work Owner Legal ow...

Page 9: ...nd laws Qualified personnel Qualified technical personnel for the design implementation and certification of domestic electrical installations in accordance with local regulations and the energy suppl...

Page 10: ...nance and decommissioning of the product must only be carried out by qualified and authorised personnel The qualified installation technician must be thoroughly familiar with DazeBox and the procedure...

Page 11: ...11...

Page 12: ...of the protective conductor between the vehicle and the mains during charging This control is necessary to ensure that no hazardous voltage can be discharged through accidental contact by unaware per...

Page 13: ...N Serial number of DazeBox SN Nominal data of DazeBox Product name CE marking The nameplate is located on the rear side of the charging station E in the picture below The data shown may vary depending...

Page 14: ...ngibile possibile identificare ugualmente il numero seriale SN estraendo il coperchio rimovibile frontale il codice su una piccola etichetta applicata nella parte inferiore dell involucro possibile tr...

Page 15: ...1 Casing 2 Removable cover 3 Status LED 4 Charging cable with Type 2 connector 5 Connector holder 6 Electrical system with protectors and cables not included 15...

Page 16: ...IEC 62196 2 EVSE standard IEC 61851 1 IEC 61851 21 CE Marking Yes Warranty 2 years Charging mode Mode 3 Connector cable length Type 2 m 3 5 7 5 7 General specifications Degree of protection IP55 IK08...

Page 17: ...from photovoltaics Yes optional No User interface Status indicator RGB LED Connectivity Bluetooth WiFi User interface Daze App for Android and iOS External master communication protocol Modbus RTU 3...

Page 18: ...uctions below The Solar Boost function detects any surplus energy produced not consumed internally by the building and transferred to the grid via the two way meter and dedicates it to recharging the...

Page 19: ...nd setting up DazeBox via Bluetooth 1 Download the App via Google Play or App Store 2 Add your DazeBox enter the Serial Number and PUK of the wallbox This data can be found on a card inside the DazeBo...

Page 20: ...facturer or qualified personnel Do not remove safety symbols warning notices cable labels or nameplates 4 1 Choice of the installation site DazeBox is designed to be installed fixed to the wall Theref...

Page 21: ...sures and rescue routes at the installation location if possible be protected from direct exposure to rain e g to prevent deterioration due to weathering freezing hail damage or similar be protected f...

Page 22: ...cks The device parts are protected by cardboard packaging After storage and transport to the installation site and immediately before installation prepare the device by taking it out of the box and re...

Page 23: ...e the earth resistance and cannot start charging if a certain threshold is exceeded Please refer to the technical documentation of the vehicle In any case it is recommended not to exceed 100 for insta...

Page 24: ...eaker RCD DazeBox must be connected to a mains supply protected by an earth leakage circuit breaker RCD circuit breaker No other electrical circuits may be connected to this earth leakage circuit brea...

Page 25: ...ease coil The regulations require the installation of a minimum voltage trip in the supply cabinet The tripping device intervenes by actuating the circuit breaker following an opening of the control c...

Page 26: ...method voltage drop cable length required power or current intensity We recommend using flexible cables to connect DazeBox for ease of wiring especially with large cable cross sections Parameter Spec...

Page 27: ...ngth 10 mm Cable length coil to DazeBox Cable outer diameter for passage through the DazeBox cable gland diaphragm between 4 5 and 5 5 mm Other important recommendations It is recommended to use a lig...

Page 28: ...ulating Power Management kWh domestic meter L01 Power cable multi core 6 mm2 conductors L02 2 core cable 2x0 5 mm2 for release coil connection to terminals BRK1 and BRK2 dry contact L03 Integrated cha...

Page 29: ...29...

Page 30: ...Wiring diagram of three phase DazeBox 30...

Page 31: ...either pass through the cable glands at the bottom of the EVSE or through the hole to be opened provided at the back of the DazeBox underlay passage In the latter case open the hole to the desired si...

Page 32: ...er is provided for DazeBox versions with 5 m and 7 m cable which must be installed at a height of 90 100 cm above the floor A space of at least 20 cm must be left around the charging station at the si...

Page 33: ...33...

Page 34: ...pencil using the drilling template A4 sheet supplied Measure the distance to the floor with a tape measure and the perpendicularity of the sheet with a spirit level 2 Drill the holes in the wall usin...

Page 35: ...4 Remove the DazeBox cover embedded in the casing using the notch at the bottom 5 Place DazeBox on the holes in the wall and secure it using the screws provided 35...

Page 36: ...the 4 screws shown in the figure with a screwdriver 4 6 DazeBox single phase electrical connection This section explains the electrical connection of the single phase DazeBox to a single phase system...

Page 37: ...odel once the casing has been opened it looks inside like the drawing in the figure above DazeBox must be connected to a mains supply protected by an earth leakage circuit breaker and a circuit breake...

Page 38: ...Section 4 4 2 Shorten the connecting cables to the appropriate length avoid leaving too much cable margin Use ferrule tips 3 Connect line L neutral N and earth PE as indicated on the board to the pus...

Page 39: ...4 7 Three phase DazeBox electrical connection This section explains the electrical connection of the three phase DazeBox to a three phase system If your DazeBox is single phase skip to section 4 6 39...

Page 40: ...odel once the casing has been opened it looks inside like the drawing in the figure above DazeBox must be connected to a mains supply protected by an earth leakage circuit breaker and a circuit breake...

Page 41: ...cting cables to the appropriate length avoid leaving too much cable margin Use ferrule tips 3 Connect line 1 L1 line 2 L2 line 3 L3 neutral N and earth conductor PE as indicated on the board to the pu...

Page 42: ...be connected to the same phase that supplies the DazeBox Example If terminals L1 L2 L3 N of DazeBox are connected to L3 L1 L2 N of the system then the current sensors of the Power Management must be...

Page 43: ...st be taken into consideration If more than one DazeBox is installed on the system only one can activate the Power Management function any other DazeBoxes installed downstream of the same meter must b...

Page 44: ...PG on the underside of the wallbox This cable gland has two 5 mm blind holes one for the two core cable from the release coil the other for the Power Management see Dynamic Power Management Manual To...

Page 45: ...o contacts are interchangeable 4 11 Configuration guide DazeBox installation involves configuring the wallbox according to the desired usage scenario with or without Power Management and Solar Boost a...

Page 46: ...ed on the top left of the internal circuit board The switches on the selector are individually numbered from 1 to 8 and must be set according to the combinations given in the tables below The tables s...

Page 47: ...ve Power Management on single phase meter without Solar Boost Table 4 3 Three phase powered DazeBox with active Power Management on three phase meter without Solar Boost Table 4 4 DazeBox powered sing...

Page 48: ...Single phase 1P Three phase 3P Table 4 1 Single phase fixed power DazeBox Table 4 3 Single phase DazeBox with active PM Table 4 5 Single phase DazeBox with active PM on three phase system Table 4 2 48...

Page 49: ...drawn by DazeBox A Maximum power absorbed by DazeBox kW 1 2 3 4 5 6 7 8 0 0 0 0 0 0 0 0 6 5 1 5 0 0 0 0 0 0 0 1 7 5 1 7 0 0 0 0 0 0 1 0 8 7 2 0 0 0 0 0 0 0 1 1 10 0 2 3 0 0 0 0 0 1 0 0 10 9 2 5 0 0 0...

Page 50: ...0 0 1 1 0 13 9 9 6 0 0 0 0 0 1 1 1 15 2 10 5 0 0 0 0 1 0 0 0 17 4 12 0 0 0 0 0 1 0 0 1 19 6 13 6 0 0 0 0 1 0 1 0 21 7 15 1 0 0 0 0 1 0 1 1 23 9 16 6 0 0 0 0 1 1 0 0 26 1 18 1 0 0 0 0 1 1 0 1 28 3 19 6...

Page 51: ...power of the three phase meter kW 1 2 3 4 5 6 7 8 0 1 1 0 0 0 0 0 26 1 6 0 0 1 1 0 0 0 0 1 30 4 7 0 0 1 1 0 0 0 1 0 32 0 8 0 0 1 1 0 0 0 1 1 32 0 9 0 0 1 1 0 0 1 0 0 32 0 10 0 0 1 1 0 0 1 0 1 32 0 15...

Page 52: ...Combination switch Maximum current drawn by DazeBox A Contractual power of the single phase meter kW 1 2 3 4 5 6 7 8 0 1 0 1 0 0 0 0 32 0 3 0 0 1 0 1 0 0 0 1 32 0 3 5 0 1 0 1 0 0 1 0 32 0 4 0 0 1 0 1...

Page 53: ...zes that the decision not to use Power Management is limiting it is enough to switch on an energy hungry appliance such as a washing machine or hairdryer both with a minimum power output of 1 8 kW tog...

Page 54: ...lation Clean the connection area remove residual material and dirt Check the correct attachment of all terminal connections After following the installation procedure outlined above step by step reass...

Page 55: ...ged DazeBox the following instructions must be followed in order to avoid the risk of electrocution do not use the device if it is damaged report the presence of the damaged device so that it is not u...

Page 56: ...the connector to the electric vehicle 4 The car is connected and charging The LED status indicator of the DazeBox is BLUE 5 If the vehicle requests to suspend or interrupt the charging process the LE...

Page 57: ...57...

Page 58: ...d be placed neatly in the connector holder in the center of the DazeBox In the case of DazeBoxes with a 5 meter or 7 meter long charging cable wrap the cable around the cable holder provided so that i...

Page 59: ...zeBox the following instructions must be followed in order to avoid the risk of electrocution do not use the device if it is damaged report the presence of the damaged device so that it is not used by...

Page 60: ...e outside of the wallbox only after it has been switched off Avoid abrasive sponges solvents or splashing water Inspect the casing and charging cable periodically for possible damage Differential devi...

Page 61: ...ssion while waiting for sufficient power availability to charge DazeBox can signal this status if the Power Management function has been activated charging will resume automatically when sufficient cu...

Page 62: ...ts of the connector E06 7 Excessive current consumption detected Charging interrupted vehicle draws more current than permitted E09 10 Detection invalid CP signal Invalid voltage detected on Control P...

Page 63: ...erature management DazeBox monitors its internal temperature to prevent overheating and protect electronic components When the temperature rises above the recommended thresholds DazeBox limits the cha...

Page 64: ...allbox must be decommissioned i e taken out of service To dismantle the charging station 1 Follow points 4 and 6 of Chapter 4 5 Assembly 2 In the case of single phase DazeBoxes disconnect the cables f...

Page 65: ...3 In the case of DazeBox 3P disconnect the cables from terminals L1 L2 L3 N and PE and remove them from the wallbox by pulling them through the cable gland A 65...

Page 66: ...nting 6 Replace the top cover on the casing 8 2 Storage In case you wish to dismantle and store DazeBox for future use these precautions must be observed in order to maintain its operability clean the...

Page 67: ...The relative humidity of the air must not exceed 95 and condensation must be avoided 67...

Page 68: ...ional and national legislation N to drawing Component Waste type 1 Charging Cable RAEE 2 LED PCB RAEE 3 DZCOB PCBS RAEE 4 Battery Alkaline batteries 5 Spacers and screws Metal waste Packaging material...

Page 69: ...69...

Page 70: ...NOTES 70...

Page 71: ...71...

Page 72: ...72...

Page 73: ...CUSTOMER SERVICE PLEASE CALL 035 1983 1355 From Monday to Friday 8 30 13 00 14 00 18 00 FOLLOW US ON...

Reviews: