Table 4.2.
Three-phase fixed power DazeBox.
Combination switch
Maximum current drawn
by DazeBox on each
phase of the system [A]
Maximum power
absorbed by DazeBox 3P
[kW]
1 2 3 4 5 6 7 8
0 0 0 0 0 0 0 0
6,5
4,5
0 0 0 0 0 0 0 1
7,5
5,2
0 0 0 0 0 0 1 0
8,7
6,0
0 0 0 0 0 0 1 1
10,0
6,9
0 0 0 0 0 1 0 0
10,9
7,5
0 0 0 0 0 1 0 1
12,2
8,4
0 0 0 0 0 1 1 0
13,9
9,6
0 0 0 0 0 1 1 1
15,2
10,5
0 0 0 0 1 0 0 0
17,4
12,0
0 0 0 0 1 0 0 1
19,6
13,6
0 0 0 0 1 0 1 0
21,7
15,1
0 0 0 0 1 0 1 1
23,9
16,6
0 0 0 0 1 1 0 0
26,1
18,1
0 0 0 0 1 1 0 1
28,3
19,6
0 0 0 0 1 1 1 0
30,4
21,1
0 0 0 0 1 1 1 1
32,0
22,2
Table 4.3.
Single-phase DazeBox with active Power Management.
Combination switch
Maximum current drawn
by DazeBox [A]
Contractual power of the
single-phase meter
[kW]
1 2 3 4 5 6 7 8
0 1 0 0 0 0 0 0
13,0
3,0
0 1 0 0 0 0 0 1
15,2
3,5
0 1 0 0 0 0 1 0
17,4
4,0
0 1 0 0 0 0 1 1
19,6
4,5