WARNING 

D

eath, serious injury, or fire hazard could result from improper connection of this instrument. Read and understand

 

this 

manual before connecting this instrument. Follow all installation and operating instructions while using this instrument. 

Connection of this instrument must be performed in compliance with the National Electrical Code (ANSI/NFPA 70-2014) of 
USA and any additional safety requirements applicable to your installation. 

Installation, operation, and maintenance of this instrument must be performed by qualified personnel only. The National 
Electrical Code defines a qualified person as “one who has demonstrated the skills and knowledge related to the construction 
and operation of the electrical equipment and installations, and who has received safety training on the hazards involved.” 

Qualified personnel who work on or near exposed energized electrical conductors must follow applicable safety related 
work practices and procedures including appropriate personal protective equipment in compliance with the Standard for 
Electrical Safety Requirements for Employee Workplaces (ANSI/NFPA 70E-2012) of USA and any additional workplace safety 
requirements applicable to your installation. 

ADVERTENCIA 

Una conexión incorrecta de este instrumento puede producir la muerte, lesiones graves y riesgo de incendio. Lea y entienda 
este manual antes de conectar. Observe todas las instrucciones de instalación y operación durante el uso de este 
instrumento. 

La conexión de este instrumento a un sistema eléctrico se debe realizar en conformidad con el Código Eléctrico Nacional 
(ANSI/NFPA 70-2014) de los E.E.U.U., además de cualquier otra norma de seguridad correspondiente a su 
establecimiento. 

La  instalación,  operación  y  mantenimiento  de  este  instrumento  debe  ser  realizada  por  personal  calificado  solamente.  El 
Código Eléctrico Nacional define a una persona calificada como "una que esté familiarizada con la construcción y operación del 
equipo y con los riesgos involucrados." 

El personal cualificado que trabaja encendido o acerca a los conductores eléctricos energizados expuestos debe seguir 
prácticas y procedimientos relacionados seguridad aplicable del trabajo incluyendo el equipo protector personal apropiado 
en conformidad con el estándar para los requisitos de seguridad eléctricos para los lugares de trabajo del empleado (ANSI/
NFPA 70E-2012) de los E.E.U.U. y cualquier requisito de seguridad adicional del lugar de trabajo aplicable a su instalación. 

AVERTISSEMENT 

Si l'instrument est mal connecté, la mort, des blessures graves, ou un danger d'incendie peuvent s'en suivre. Lisez 
attentivement ce manuel avant de connecter l'instrument. Lorsque vous utilisez l'instrument, suivez toutes les 
instructions d'installation et de service. 

Cet instrument doit être connecté conformément au National Electrical Code (ANSI/NFPA 70-2014) des Etats-Unis et à 
toutes les exigences de sécurité applicables à votre installation. 

Cet  instrument  doit  être  installé,  utilisé  et  entretenu  uniquement  par  un  personnel  qualifié.  Selon  le  National  Electrical 
Code, une personne est qualifiée si "elle connaît bien la construction et l'utilisation de l'équipement, ainsi que les dangers 
que cela implique". 

Le personnel qualifié qui travaillent dessus ou s'approchent des conducteurs électriques activés exposés doit suivre des 
pratiques en matière et des procédures reliées par sûreté applicable de travail comprenant le matériel de protection 
personnel approprié conformément à la norme pour des conditions de sûreté électriques pour les lieux de travail des 
employés  (ANSI/NFPA 70E-2012) des Etats-Unis et toutes les conditions de sûreté additionnelles de lieu de travail 
applicables à votre installation. 

Summary of Contents for IL70A

Page 1: ...CCW for torque cells the IL70A contains a symmetry adjustment which corrects for negative span or slope of the transducer The Model IL70A is best calibrated by means of a two point dead weight or shun...

Page 2: ...miento de este instrumento debe ser realizada por personal calificado solamente El C digo El ctrico Nacional define a una persona calificada como una que est familiarizada con la construcci n y operac...

Page 3: ...r elektrische Sicherheitsauflagen f r Angestellt Arbeitspl tze ANSI NFPA 70E 2012 der Vereinigten Staaten und alle zus tzlichen Arbeitsplatzsicherheitsauflagen folgen die auf Ihre Installation anwend...

Page 4: ...y que el material aislante no tenga rajaduras Reemplace de inmediato cualquier parte defectuosa Mesures de S curit Les mesures de s curit suivantes doivent tre prises chaque fois qu un type de connex...

Page 5: ...henden Schaltung hergestellt werden Tragen Sie Schutzbrillen und Isolierhandschuhe wenn Sie Anschl sse an den Stromkreisen vornehmen H nde Schuhe und Fu boden m ssen trocken sein wenn Sie Anschl sse a...

Page 6: ...ble up to 70mA Power Supply 11 28 Vdc regulated 2 watts max Analog Ouput selectable 0 to 5 0 to 10 Vdc 4 12 20 or 4 20mA 20 over range voltage only Operating Temperature 10 to 70 Degrees C 5 to 95 rel...

Page 7: ...Label Function 1 2 3 4 5 6 7 8 Analog Output SHP SHN NC Analog Common Power Common 24 Vdc Shield Signal Output Shunt Positive switch input Shunt Negative swith input No connection Signal Output Power...

Page 8: ...located between the two wiring connectors Below are the appropriate wiring and jumper selections depending on the application using the recommended 7 wire configuration TRANSDUCER CONNECTIONS IL70A 2...

Page 9: ...st the instrument sensitivity accordingly Place the jumper on the IL70A to INT to enable the 59K Ohm resistor A one percent 59 kilohm calibration resistor is installed in the IL70A at the factory The...

Page 10: ...o obtain your nominal full scale analog output Use Fine Span control to adjust the signal to the precise value required or for an analog value that correspondes with the appropriate Shunt Calibration...

Page 11: ...l The Remote Cal function provides a convenient method of periodically monitoring calibration of the instrument in the positive or negative realm Switch 1 Mode current I or voltage analog output Switc...

Page 12: ...by the direction of the loading or off zero reading c The inability to balance correctly where the instrument output readstotally off scale and the BALANCE controls have no authority can very likely...

Page 13: ...Fig 4 Star Bridge DC Strain Gage Conditoner Module IL70A...

Page 14: ...oduct or products for any reason the customer must call Daytronic Customer Support Services at ALL EQUIPMENT TO BE REPAIRED OR REPLACED UNDER WARRANTY MUST BE RETURNED TO THE FACTORY Once the customer...

Reviews: