11
Step 10:
Install the lamp key into the controller (MCXS/KMCXS systems only). The key
always comes packaged with the lamp and sits on the connector. With the key
removed from the lamp, orient it so the label is upright and facing you. The key
will plug into the lamp key port on the right side of the controller (Figure 8).
Note: All replacement lamps will come with a key. If you have the MCS
controller, the key should be discarded as it can’t be used in the MCS controller.
Step 11:
Plug the lamp connector into the lamp. Note the keying for proper
alignment (see Figure 8). Insert the lamp connector into the gland nut and
turn the connector approximately ¼ turn to lock the connector to the gland
nut as in Figure 10.
Figure 9. Lamp Key Installation
Figure 10. Lamp Connector
Step 12:
Tighten the captive earth screw to the earth lug on the UV chamber to
ensure proper earthing.
Figure 11. Earth Screw Connection
Step 13:
Your system is now ready to be plugged into the appropriate residual
current device (RCD) protected outlet. Refer to the following section before
any water is allowed to flow through the system.
Note: Installation of your Microlene disinfection systems must comply with
applicable provincial/state & local regulations.