MCS Controllers
Simplistic in operation, these systems feature a tri-colour LED that
indicating system status and a 4-digit display to indicate lamp life
remaining. Pressing the button will change the display to indicate total
running time. When the UV lamp is on and within its operating age,
the LED will be green. When the UV lamp is not on or the lamp life
has expired, the LED will be illuminated red and an audible buzzer will
sound. To remedy this condition, the UV lamp must be replaced with
a new genuine Microlene UV lamp.
MCXS Controllers
A full colour LCD screen provides the user with a detailed description
of the system’s performance in addition to providing any applicable
fault messages and system diagnostics. The controller can be used as
both a non-monitored and UV monitored system. If a true UV monitor
is required, simply add the optional UV sensor module to the “infinite
expandability port” located on the right side of the controller. Simply
plug in an optional UV sensor module into the expandability port of
a Microlene controller and the system will now monitor the UV intensity
of the system!
MCXS Power-up Sequence
On start up, the controller will run through a diagnostic start-up and the sequence will
be displayed as follows on the colour LCD:
Next, the controller checks for and initializes any optional modules that may be
attached to the system.
UV Sensor
Solenoid
Module Check
Module Check
OR
OR