*  Installation and operating instructions are included with the product when purchased new. 

They may also be found on our website.

AUSTRALIA
Customer Service Centre

6 Lakeview Drive,

Scoresby, Australia 3179

Ph: 

1300 232 839

Fax: 

1300 369 119

Email: [email protected]

Davey Water Products Pty Ltd

Member of the GUD Group

ABN 18 066 327 517

NEW ZEALAND
Customer Service Centre

7 Rockridge Avenue,

Penrose, Auckland 1061

Ph: 

0800 654 333

Fax: 

0800 654 334

Email: [email protected]

® Davey is a registered trademark of Davey Water Products Pty Ltd.  © Davey Water Products Pty Ltd 2021.

daveywater.com

DWP1390-1

Davey Warranty

Products manufactured by Davey Water Products Pty. Ltd. are warranted to the original user only to be free of defects in 

material and workmanship for a period as specified below. This warranty only applies to the original purchaser and is 

not transferable.

UV Systems

Ten (10) year Limited Warranty on the stainless steel chambers, from the date of original purchase, or installation (proper 

documentation required for verification).

Electronics

Three (3) year Limited Warranty on the ballasts and controllers, from the date of original purchase, or installation (proper 

documentation required for verification).

UV Lamps, UV Sensors & Quartz Sleeves

One (1) year Limited Warranty on all US WATER ultraviolet lamps, UV sensors and quartz sleeves from the date of original 

purchase, or installation (proper documentation required for verification).

This warranty does not cover normal wear and tear or apply to a product that has:

•  been subject to misuse, neglect, negligence, damage or accident

•  been used, operated or maintained other than in accordance with Davey’s instructions

•  not been installed in accordance with the Installation Instructions or by suitably qualified personnel 

•  been modified or altered from original specifications or in any way not approved by Davey

•  had repairs attempted or made by other than Davey or its authorised dealers

•  been subject to abnormal conditions such as incorrect voltage supply, lightning or high voltage spikes, or damages 

from electrolytic action, cavitation, sand, corrosive, saline or abrasive liquids,

The Davey warranty does not cover replacement of any product consumables or defects in products and components 

that have been supplied to Davey by third parties (however Davey will provide reasonable assistance to obtain the 

benefit of any third-party warranty).

To make a warranty claim:

•  If the product is suspected of being defective, stop using it and contact the original place of purchase. Alternatively, 

phone Davey Customer Service or send a letter to Davey as per the contact details below

•  Provide evidence or proof of date of original purchase

•  If requested, return the product and/or provide further information with respect to the claim. Returning the product 

to the place of purchase is at your cost and is your responsibility.

•  The warranty claim will be assessed by Davey on the basis of their product knowledge and reasonable judgement 

and will be accepted if:

-  a relevant defect is found

-  the warranty claim is made during the relevant warranty period; and

-  none of the excluded conditions listed above apply

•  The customer will be notified of the warranty decision in writing and if found to be invalid the customer must 

organise collection of the product at their expense or authorise its disposal.

If the claim is found to be valid Davey will, at its option, repair or replace the product free of charge.

The Davey warranty is in addition to rights provided by local consumer law. You are entitled to a replacement or 

refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also 

entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not 

amount to a major failure.

For any internet connected products the consumer is responsible for ensuring a stable internet connection. In the event 

of a network failure the consumer will need to address the concern with the service provider. Use of an App is not a 

substitute for the User’s own vigilance in ensuring the product is working to expectation. Use of a Smart Product App 

is at the User’s own risk. To the fullest extent permitted by law Davey disclaims any warranties regarding the accuracy, 

completeness or reliability of App data. Davey is not responsible for any direct or indirect loss, damage or costs to the 

User arising from its reliance on internet connectivity. The User indemnifies Davey against any claims or legal actions 

from them or others relying on internet connectivity or App data may bring in this regard.

Products presented for repair may be replaced by refurbished products of the same type rather than being repaired.  

Refurbished parts may be used to repair the products. The repair of your products may result in the loss of any user-

generated data. Please ensure that you have made a copy of any data saved on your products.

To the fullest extent permitted by law or statute, Davey shall not be liable for any loss of profits or any consequential, 

indirect or special loss, damage or injury of any kind whatsoever arising directly or indirectly from Davey products. This 

limitation does not apply to any liability of Davey for failure to comply with a consumer guarantee applicable to your 

Davey product under local laws and does not affect any rights or remedies that may be available to you under local laws.

For a complete list of Davey Dealers visit our website (daveywater.com) or call:

Summary of Contents for microlene MCS

Page 1: ...he operator of this equipment Aquashield Centurion 3 Stage UV Disinfection System Models MCS MCXS without cartridges KMCS KMCXS with cartridges included Installation and Operating Instructions Flow Rate 30mJ cm2 95 UVT 57 L min AS NZS 3497 ...

Page 2: ... reassurance that your family will have access to safe drinking water throughout your entire home protecting from microbiological contamination This is a chemical free process which is simple in its concept and effective in its abilities to inactivate microorganisms present in the water supply Simple maintenance Continuous disinfection Safe water Microlene makes it that easy These instructions are...

Page 3: ...Operation 13 MCS Controllers 14 MCXS Controllers 14 MCXS Power up Sequence 14 MCXS Operational Screens 15 MCXS with optional sensor Operational Screens 16 Lamp Countdown Sequence 16 Lamp Replacement MCS systems 17 Lamp Replacement MCXS systems 17 QR Codes 17 System Troubleshooting 18 Temperature Management Devices 19 Expansion Modules 20 Microlene Aquashield Centurion UV System Specifications 21 L...

Page 4: ...l capabilities or lack of experience and knowledge unless they have been given supervision or instruction 6 Children should be supervised so that they do not play with the appliance 7 To avoid possible electrical shock use only with a properly earthed electrical outlet Appliances that are obviously damaged must not be operated 8 Never perform any maintenance to the system unless you are comfortabl...

Page 5: ...erials Inlet outlet connections Teflon thread tape Water Quality Parameters UV disinfection is extremely effective against microorganisms but only if the UV light can pass through the water it needs to treat This means that the quality of your water is very important in order to ensure complete disinfection Treated water should be tested for at least the parameters listed below If the water exceed...

Page 6: ... MC HOSL 7 UV Chamber 8 Clamps 9 Flexible Hose 10 Mounting Plate 11 Filter Cartridges Only KMCS and KMCXS have filters included Part 20PP20J 20 20 micron sediment Part 1PS20J 20 1 micron sediment 12 Filter Housings Part DM160018 double filter housing two 20 sumps and caps 13 Mounting Screws 14 Filter Wrench Part WFH45 15 UV Sensor optional module Part MCXS UVS 16 IEC Power Cable Part MC CONT PC Au...

Page 7: ...or above the chamber IMPORTANT All Microlene Aquashield Centurion UV Disinfection Systems are intended to be installed under a weather proof cover and should not be exposed to the elements MCS C Weather proof cover purchased separately Protects the chamber and controller from rain and direct elements Enables the 3 Stage UV system to be set up left to right or right to left for ease of installation...

Page 8: ...cating water flow which now should be indicating a flow direction of right to left Figure 2 System Orientation water inlet Step 4 Remove the stainless steel UV chamber from the two plastic clamps located on the top of the rack Carefully remove the top straps securing the chamber with the aid of a standard slot screwdriver Rotate the chamber 180 degrees with the inlet now facing to the left and the...

Page 9: ...gently remove the quartz sleeve from its packaging being careful not to touch the sleeve or lamp with your hands The use of cotton gloves is recommended for this procedure as oils from the hands can leave residue on the sleeve and lamp which can ultimately block the UV light from getting to the water Carefully slide the sleeve into the chamber until you can feel it hit the opposite end of the cham...

Page 10: ... controller Align the flat portion so it faces the gland nut end and matches up with the half metal lip on the sensor port see Figure 6 Insert the sensor so it is fully seated and hand tighten the sensor nut Insert the sensor connector into the IEP port located on the right side of the controller Figure 7 For the sensor to be recognized by the controller the controller power must be plugged in las...

Page 11: ... lamp Note the keying for proper alignment see Figure 8 Insert the lamp connector into the gland nut and turn the connector approximately turn to lock the connector to the gland nut as in Figure 10 Figure 9 Lamp Key Installation Figure 10 Lamp Connector Step 12 Tighten the captive earth screw to the earth lug on the UV chamber to ensure proper earthing Figure 11 Earth Screw Connection Step 13 Your...

Page 12: ...ng Step 4 Reinstall the filter cartridge into the sump and flush the chlorine solution by opening all faucets until chlorine can no longer be detected Your home has now been completely disinfected with your Microlene Aquashield Centurion UV system ready to inactivate any microorganisms that enter the home Cleaning the Quartz Sleeve Depending on the water quality the quartz sleeve may require perio...

Page 13: ...ise sensor nut from the chamber and pull the sensor slowly out of the sensor port Step 6 Holding the sensor in your hand wipe the flat portion sensor face of the sensor with isopropyl alcohol using a clean lint free cloth Step 7 Replace sensor following step 9 from the installation section of the manual Operation Microlene systems come with a feature laden controller that incorporates both the lam...

Page 14: ...ription of the system s performance in addition to providing any applicable fault messages and system diagnostics The controller can be used as both a non monitored and UV monitored system If a true UV monitor is required simply add the optional UV sensor module to the infinite expandability port located on the right side of the controller Simply plug in an optional UV sensor module into the expan...

Page 15: ... ready to disinfect water flow all detected modules lamp reaching max output successful start up MCXS Operational Screens On systems without the UV monitor the default screen shows the Microlene Home Screen At any point during operation the user is able to scroll through the Microlene Home Screen Lamp life remaining QR Code Contact Info and Maintenance Parts screens by pressing the button located ...

Page 16: ...tant audible alarm is given This alternates with a screen indicating water may be unsafe for consumption With the solenoid module the controller de activates the solenoid valve shutting off all water flow audible chirp every 15 seconds audible chirp every 15 seconds constant audible alarm cycles with red low uv screen Lamp Countdown Sequence The system counts down the number of days until a lamp c...

Page 17: ...with step 11 page 11 for instructions on installing the new lamp To reset the timer in the controller firmly hold down the button on the controller for 10 seconds The controller will read rSt3 rSt2 rSt1 and then beep The button can now be released the lamp countdown timer has been reset The lamp key that comes with the replacement lamp will not be required on the MCS system and can be discarded La...

Page 18: ... the chamber or on the Maintenance parts screen Low UV Intensity Remove and clean the quartz sleeve and sensor Check water quality meets requirements on page 5 and add filtration as required Replace lamp Wrong lamp or sensor installed Replace component with proper model as indicated The UV sensor is no longer communicating with the system Ensure all modules are connected properly to the system and...

Page 19: ... heading Boil Water Advisory If any failure occurs on a Microlene UV system the water must not be used for human consumption until the system is returned to a safe operational mode If the water is used for human consumption during this period the water must be boiled minimum 20 minutes at a full boil prior to consumption Temperature Management Devices Your Microlene system is designed to run conti...

Page 20: ... of contacts In normal operation the OK and COM contacts will be connected and in a fault condition Low UV Lamp fail Power Fail the Fault and COM contacts will be connected Maximum Contact Rating is 30V 1A use 16 22 AWG Order PN DMMOD RAM SOLENOID CONNECTION MODULE Connects a NORMALLY CLOSED line voltage solenoid valve to the controller On a non monitored system the solenoid will only close on a l...

Page 21: ...lamp Power Watts 57 48 230V Replacement Lamp MC HOLP Replacement Sleeve MC HOSL Chamber Dimensions 8 9 x 50 8 cm 3 5 x 20 Chamber Material Polished 316L Stainless Steel A249 Pressure Rated Tubing Controller Dimensions 21 8 x 10 7 x 8 9 cm 8 6 x 4 2 x 3 5 Operating Pressure 827kPa 120PSI Operating Water Temperature 2 40 C 36 104 F UV Monitor not available OPTIONAL optional UV module sold separately...

Page 22: ...22 NOTES ...

Page 23: ...23 ...

Page 24: ...of date of original purchase If requested return the product and or provide further information with respect to the claim Returning the product to the place of purchase is at your cost and is your responsibility The warranty claim will be assessed by Davey on the basis of their product knowledge and reasonable judgement and will be accepted if a relevant defect is found the warranty claim is made ...

Reviews: