78
18. Direct Connection of the RMC-185+ KMU
Controller and KMU-100+
The RMC-185 KMU Controller is designed to control the KMU-100 via the RS-422 interface
using the VISCA Command Protocol.
The RMC-185 panel style design allows easy control of the KMU-100 with the hard keys
giving the user quick access to main functions of the KMU-100.
18.1 Direct Connection to KMU-100
To use the RMC-185 KMU Controller to directly control the KMU-100 4K Multi-Camera
Processor, connect the RS-422 port (9 PIN D-Sub) on the KMU-100’s rear panel to the RJ-45
port of the RMC-185 using any RJ-45 cable. The RJ-45 to 9 PIN D-Sub cable wiring scheme is
shown below.
P1 (RJ45)
P2 (DB9M)
Green/White
1
------------------ 1/6/4/9/5
Green
2
------------------
X
Orange/White
3
------------------
8
Blue
4
------------------
2
Blue/White
5
------------------
7
Orange
6
------------------
3
Brown/White
7
------------------
X
Brown
8
------------------
X
Summary of Contents for KMU-100
Page 1: ...PROCESSOR Instruction Manual ...
Page 54: ...54 11 System Diagram of the RMC 185 and KMU 100 Connection ...
Page 62: ...62 Power On Off Switch Switches the device ON OFF ...
Page 81: ...81 21 Dimensions KMU 100 KMU 100 ...
Page 82: ...82 RMC 185 RMC 185 Unit mm ...
Page 86: ...86 Note ...
Page 87: ...87 Note ...