
60
H-Class
System Settings (continued)
Menu Item
Details
VOID DISTANCE
Sets the distance to print VOID on a faulted label,
where:
(0.10 to 2.00 in.)
0.50
Is the distance, measured from the trailing edge,
which establishes the text size.
VOID will not be printed if insufficient text space
exists or if the fault occurred after printing
completed. Also, the text can be customized; see
the
Class Series 2 Programmer’s Manual
.
RETRY COUNT
Sets the number of printing attempts before declaring
a fault, where:
(0 – 3)
1
Is the count.
Greater than 1 (one) counts are valid only when
Linear Scanner or RFID equipped.
BACKFEED ON CLEAR
Determines positioning after a fault is cleared, where:
ENABLED
Automatically positions the label.
DISABLED
No label positioning occurs, as the location is assumed
correct.
If reloading, you must place the media at the SOP
position.
SCL FONT BOLD FACTOR
Sets a scalable font boldfacing amount, where:
(1 – 36)
08
Is the setting, based on an incrementing scale where
eight (08) is nominal.
Summary of Contents for H-4212
Page 1: ...Operator s Manual ...
Page 2: ......
Page 6: ......
Page 16: ...6 H Class ...
Page 40: ...30 H Class ...
Page 86: ...76 H Class ...
Page 142: ...132 H Class ...
Page 146: ...136 H Class ...
Page 150: ...140 H Class ...
Page 158: ...148 H Class ...
Page 162: ...152 H Class ...
Page 176: ...166 H Class ...
Page 180: ......