Sequence Using Command Box
Turn ON the main power supply switch in the back panel of the control rack. The laser
marker turns on and goes in booting-up state. During booting up state, the status LED
on the control rack blink green.
Wait until booting-up has ended: the status LED on the control rack is steady green. The
laser marker is in WAIT FOR START state.
Figure 7: Wait for start state
Set the Command box input signals as in the table below:
EXT_KEY
EXT_ENABLE_A
EXT_ENABLE_B
HIGH
LOW
LOW
Steady
The status LED on the rack will be blinking orange for about 30 seconds (laser source
warm-up).
Wait until laser source warm-up finishes. The status LED on the rack will be steady
orange. The laser marker is in STANDBY SHUTTER CLOSED state.